We quantified ventricular fibrillation (VF) activation rate, conduction block, and organization transmurally in pigs and dogs, whose transmural Purkinje distribution differ. In six pigs and five dogs, 75 to 100 plunge needles, containing four electrodes for the right ventricle (RV) and six electrodes for the left ventricle (LV) and septum, were inserted in vivo. Six VF episodes were electrically initiated and allowed to last for 47 to 180 seconds. From the FFT power spectra, dominant frequency (DF), an estimate of activation rate, and incidence of double peaks (DPI), an estimate of conduction block, were calculated every 8 ms at each electrode. DF was highest at the epicardium and lowest at the endocardium, whereas DPI was highest at the endocardium and lowest at the epicardium for the entire LV and the RV base in both pigs and dogs for the first 70 seconds of VF. This distribution changed little throughout the first 3 minutes of VF in pigs but reversed in dogs by 2 minutes of VF. In conclusion, estimated activation rates and conduction block incidence during VF are not uniformly distributed transmurally. During the first minute of VF, the faster activating LV base epicardium exhibits less estimated block than the slower endocardium, raising the possibility that faster activating epicardium generates wavefronts that drive the endocardium early during VF. Constancy of this pattern in pigs but its reversal by 2 minutes in dogs is consistent with the hypothesis that activation during later VF is driven by Purkinje fibers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/01.RES.0000120860.01645.17 | DOI Listing |
Am J Transl Res
December 2024
Department of Anesthesia, Hankou Hospital of Wuhan Wuhan 430014, Hubei, China.
Background: Managing postoperative pain and stress response was critical in laparoscopic myomectomy, a procedure for uterine fibroids. Ropivacaine transversus abdominis plane block (RTAPB) may offer enhanced analgesic efficacy and reduced stress responses compared to traditional analgesia.
Methods: This retrospective analysis examined 217 patients undergoing laparoscopic myomectomy at Hankou Hospital of Wuhan from June 2020 to September 2023.
Eur Heart J Case Rep
January 2025
Department of Radiological and Hematological Sciences, Section of Radiology, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8 - 00168 Rome, Italy.
Background: Cardiac strangulation (CS) from epicardial pacing leads (EPLs) is a rare and potentially lethal mechanical complication associated with epicardial pacemaker (PM) implantation.
Case Summary: We report a case of a 44-year-old-female patient presenting with chest and left shoulder pain in the absence of reported trauma with history of congenital atrioventricular block treated with epicardial PM implantation during the childhood and subsequent transvenous reimplantation over the years. Troponin I resulted within normal values and ECG, transthoracic echocardiography and chest X-ray documented no acute cardiopulmonary findings.
J Cardiovasc Electrophysiol
January 2025
Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland.
Atrial flutter (AFL), defined as macro-re-entrant atrial tachycardia, is associated with debilitating symptoms, stroke, heart failure, and increased mortality. AFL is classified into typical, or cavotricuspid isthmus (CTI)-dependent, and atypical, or non-CTI-dependent. Atypical AFL is a heterogenous group of re-entrant atrial tachycardias that most commonly occur in patients with prior heart surgery or catheter ablation.
View Article and Find Full Text PDFBMJ Open
January 2025
Department of Anesthesiology and Perioperative Medicine, Xijing Hospital of Air Force Military Medical University, Xian, Shaanxi, China
Introduction: Minimally invasive cardiac surgery (MICS) is important for enhanced recovery in cardiac surgery. However, the incidence of chronic postsurgical pain (CPSP) is high and is associated with worsened quality of recovery and life, as well as raised short-term or long-term mortality. The mechanism is not clear, and there is still a lack of safe and effective preventive measures.
View Article and Find Full Text PDFJACC Clin Electrophysiol
January 2025
Vanderbilt Heart and Vascular Institute, Nashville, Tennessee, USA. Electronic address:
Background: Programmed electrical stimulation (PES) is an essential part of ventricular tachycardia (VT) ablation procedures, but VT is not always inducible, usually for reasons that are not clear.
Objectives: This study sought to review pacing site-specific failure of PES to induce scar-related VT and to provide a potential mechanistic explanation of the phenomena using a computer simulation.
Methods: Six patients in whom aggressive PES from traditional RV pacing sites failed to induce VT, but VT was easily inducible from a nontraditional site, were reviewed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!