Ion-chromatographic determination of carbocisteine in pharmaceuticals based on non-suppressed conductimetric detection.

J Chromatogr A

Laboratory of Analytical Chemistry, Department of Chemistry, University of Athens, Panepistimiopolis, Athens 15771, Greece.

Published: February 2004

A novel method for the determination of carbocisteine (S-CMC), a mucolytic and expectorant drug with an acidic amino acid structure, was developed and validated, using non-suppressed ion-chromatographic system with conductimetric detection, and anion or cation exchange columns. Among the various combinations of column type and eluent composition tested, a cation exchange column with a 0.25 mM tri-fluoroacetic acid (TFA) as eluent in isocratic mode at 1.2 ml/min gave the best results. S-CMC was very well separated from all common amino acids (resolution > 2.6). The retention time was 3.5 min and the asymmetry factor 1.1. A linear calibration curve from 17 to 400 microg/ml (r = 0.99994), with a detection limit of 0.14 microg (5.6 microg/ml-25 microl injection volume) and a precision of 1.5% R.S.D. (100 microg/ml, n = 3) was achieved. The proposed method was applied for the determination of S-CMC content in intensely colored commercial formulations (syrups). No interference from excipients was found and the only pretreatment step was the appropriate dilution with the mobile phase. Recovery from standard additions was ranged from 96.0 to 104.9% and precision (R.S.D., n = 3) 1.8-3.6%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2003.10.111DOI Listing

Publication Analysis

Top Keywords

determination carbocisteine
8
conductimetric detection
8
cation exchange
8
ion-chromatographic determination
4
carbocisteine pharmaceuticals
4
pharmaceuticals based
4
based non-suppressed
4
non-suppressed conductimetric
4
detection novel
4
novel method
4

Similar Publications

Herein, a novel spectrofluorometric sensor is proposed for the sensitive analysis of two nonfluorescent mucolytic drugs, namely, acetylcysteine (ACT) and carbocisteine (CST), utilizing the newly synthesized 2-[(2-hydroxyethyl)-(2,8,10-trimethylpyrido[2',3':3,4]pyrazolo[1,5-a]pyrimidin-4-yl)-amino]-ethanol as a fluorescence probe (Flu. Probe). This fluorophore exhibits fluorescence emission at 445 nm upon excitation at 275 nm.

View Article and Find Full Text PDF

Efficacy and safety of mucolytics in patients with stable chronic obstructive pulmonary disease: A systematic review and meta-analysis.

Respir Investig

November 2024

Department of Environmental Medicine, Kochi Medical School, Kochi University, Oko-cho, Kohasu, Nankoku, Kochi, 780-8505, Japan.

Background: The efficacy and safety of mucolytics in patients with chronic obstructive pulmonary disease (COPD) and chronic bronchitis or exacerbations of COPD have been reported. We conducted a systematic review and meta-analysis of mucolytics in patients with stable COPD.

Methods: Reports from randomized controlled trials to evaluate the efficacy and safety of mucolytics, including ambroxol, bromhexine, carbocisteine, erdosteine, fudosteine, l-methylcysteine, and N-acetylcysteine used in patients with stable COPD were searched for in PubMed, Scopus, Embase, Web of Science, the Cochrane Library, and the Igaku Cyuo Zasshi database.

View Article and Find Full Text PDF

Purpose: Obstructive sleep apnea (OSA) is a common clinical problem that is associated with adverse cardiovascular outcomes attributed to the oxidative stress due to sympathetic overstimulation. Treatment approaches targeting oxidative stress have been tried by multiple investigators. This systematic review and meta-analysis evaluated the efficacy and safety of such approaches.

View Article and Find Full Text PDF

To assess the risk of major birth defects after first-trimester exposure to carbocisteine and ambroxol during pregnancy, we conducted a prospective cohort study using counseling data for drug use during pregnancy provided by the Japan Drug Information Institute in Pregnancy and Toranomon Hospital. Counseling information, including drug usage and participants' demographic information, was collected between April 1988 and December 2017. Pregnancy outcome data, including major birth defects, were obtained using a questionnaire administered 1 month after delivery.

View Article and Find Full Text PDF

High-resolution tandem quadrupole time-of-flight mass analysers enable new automated workflows for untargeted data evaluation of complex samples like drug products. An example of such procedure is the so-called general unknown comparative screening (GUCS), which is used for software-assisted, automated identification of components that are only present in a sample and not in a reference. The GUCS approach has been employed for the first time to detect both degradation products and reaction products in drug products.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!