Background And Purpose: Precise reproducible patient positioning is a prerequisite for conformal fractionated radiotherapy. A fixation system based on double-vacuum technology is presented which can be used for conventional as well as hypofractionated stereotactic extracranial radiotherapy.
Material And Methods: To form the actual vacuum mattress, the patient is pressed into the mattress with a vacuum foil which can also be used for daily repositioning and fixation. A stereotactic frame can be positioned over the region of interest on an indexed base plate. Repositioning accuracy was determined by comparing daily, pretreatment, orthogonal portal images to the respective digitally reconstructed radiographs (DRRs) in ten patients with abdominal and pelvic lesions receiving extracranial fractionated (stereotactic) radiotherapy. The three-dimensional (3-D) vectors and 95% confidence intervals (CI) were calculated from the respective deviations in the three axes. Time required for initial mold production and daily repositioning was also determined.
Results: The mean 3-D repositioning error (187 fractions) was 2.5 +/- 1.1 mm. The largest single deviation (10 mm) was observed in a patient treated in prone position. Mold production took an average of 15 min (10-30 min). Repositioning times are not necessarily longer than using no positioning aid at all.
Conclusion: The presented fixation system allows reliable, flexible and efficient patient positioning for extracranial stereotactic radiotherapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00066-004-1146-0 | DOI Listing |
Virtual Real
December 2024
Department of Computer Science and Software Engineering, Concordia University, Montreal, Québec Canada.
Epilepsy is a neurological disorder characterized by recurring seizures that can cause a wide range of symptoms. Stereo-electroencephalography (SEEG) is a diagnostic procedure where multiple electrodes are stereotactically implanted within predefined brain regions to identify the seizure onset zone, which needs to be surgically removed or disconnected to achieve remission of focal epilepsy. This procedure is complex and challenging due to two main reasons.
View Article and Find Full Text PDFEur J Med Res
December 2024
Department of Rehabilitation Medicine, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, No.1279 Sanmen Road, Hongkou District, Shanghai, China.
Objectives: Our aim is to investigate the effects of a innovative modular prone positioning tools on patients with acute respiratory distress syndrome (ARDS) caused by COVID-19 during awake prone positioning (AW-PP).
Methods: This prospective randomized controlled study initially enrolled 168 patients with COVID-19 due to ARDS. However, 92 were subsequently disqualified, leaving 76 patients who were randomly assigned to either the observation group (n = 38) or the control group (n = 38).
Tech Hand Up Extrem Surg
October 2024
Orthopedics-Hand Surgeon, Hospital Universitario Fundación Santafé, Department of Orthopedics and Traumatology, Bogotá, Colombia.
Radial longitudinal deficiency III and IV present as a short upper limb, functional elbow, and wrist with severe radial and palmar angulation, where the carpus articulates with the radial and palmar edge of the ulna, allowing limited mobility in a nonfunctional position. Surgical treatment aims to correct radial angulation and flexed carpal position, often altering carpal positioning over the distal ulna and impacting wrist mobility. In addition, fixation through distal ulnar epiphysis affects its growth.
View Article and Find Full Text PDFBMC Pediatr
December 2024
Department of Nursing and Midwifery, College of Health, Wellbeing and Life Sciences, Sheffield Hallam University, Sheffield, UK.
Background: Despite progress made towards SDG 3, sub-Saharan Africa lags behind the rest of the world, accounting for over 50% of global neonatal deaths. The increased number of hospital births in the region has not reciprocated the reduction in neonatal mortality rates. Sick newborns face uncertain journeys from peripheral facilities to specialized centres arriving in suboptimal conditions, which impacts their outcomes, due partly to the scarcity of dedicated neonatal transport services.
View Article and Find Full Text PDFClin Biomech (Bristol)
December 2024
Department of Orthopedic Surgery, Hiroshima University Hospital Graduate School of Biomedical and Health Sciences, Hiroshima City, Hiroshima Prefecture, Japan.
Background: Total hip arthroplasty is the preferred treatment for advanced hip osteoarthritis, yet complications like hip dislocation (0.2 %-10 %) persist due to factors such as implant design, positioning, surgical technique, and patient-specific conditions. Impingement between prosthetic components or the acetabulum and proximal femur is a primary cause of instability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!