Fetuses with complete heart block have an increased mortality with most deaths occurring in utero or during infancy. The cardiac evaluation of these fetuses is difficult since the ventricular rate is low and the heart is dilated. We have implemented a strategy that includes the biophysical profile, which assesses fetal well-being, in combination with the cardiovascular profile that assesses cardiac function and the circulation. We present two cases of fetal complete heart block in which early delivery was recommended due to worsening cardiovascular profile scores. Biophysical profile scores were normal. Both babies were successfully treated, despite having risk factors that predicted poor outcomes. We hypothesize that our management protocol initiated intervention before fetal compromise, hydrops, and myocardial damage occurred. We recommend an evaluation of heart function in addition to an assessment of fetal well-being in fetuses with complete heart block. Early delivery should be considered if there is evidence of distress and/or deteriorating cardiac function.

Download full-text PDF

Source
http://dx.doi.org/10.1038/sj.jp.7211038DOI Listing

Publication Analysis

Top Keywords

complete heart
16
heart block
16
management protocol
8
fetuses complete
8
biophysical profile
8
profile assesses
8
fetal well-being
8
cardiovascular profile
8
cardiac function
8
block early
8

Similar Publications

Background: Heart failure (HF) is a chronic, progressive condition where the heart cannot pump enough blood to meet the body's needs. In addition to the daily challenges that HF poses, acute exacerbations can lead to costly hospitalizations and increased mortality. High health care costs and the burden of HF have led to the emerging application of new technologies to support people living with HF to stay well while living in the community.

View Article and Find Full Text PDF

Objectives: This fourth report aimed to provide insights into patient characteristics, outcomes, and standardized outcome ratios of patients implanted with durable Mechanical Circulatory Support across participating centers in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) registry.

Methods: All registered patients receiving durable mechanical circulatory support up to August 2024 were included. Expected number of events were predicted using penalized logistic regression.

View Article and Find Full Text PDF

Introduction: Decreased left atrial appendage emptying velocity (LAAV) is a marker for thrombus formation. This study evaluates the association between LAAV and inflammatory indices in non-valvular atrial fibrillation (AF) patients.

Methods: The study population was 1428 patients with AF, 875 of whom enrolled.

View Article and Find Full Text PDF

Aims: A single-blinded, multicentred randomized controlled trial (RCT) was employed to examine the effectiveness of a 3-month telephone follow-up, a telephone follow-up with education before discharge, or education only before discharge on the heart failure (HF) knowledge, HF self-care management, and health-related quality of life (HR-QoL) in patients with HF by a nurse specialist.

Methods And Results: This is a multicentre RCT with three different intervention groups (IGs) and one control group. Participants in the first IG received education on HF self-management principles before discharge.

View Article and Find Full Text PDF

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!