A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

IGBT-based kilovoltage pulsers for ultrasound measurement applications. | LitMetric

IGBT-based kilovoltage pulsers for ultrasound measurement applications.

IEEE Trans Ultrason Ferroelectr Freq Control

Gammell Applied Technologies, Exmore, VA 23350, USA.

Published: December 2003

Two high-voltage pulser designs are presented that offer advantages in some ultrasound measurement applications, such as driving thick ultrasonic source transducers used for broadband measurements of attenuation or hydrophone frequency response and directivity. The pulsers use integrated gate bipolar transistors (IGBTs) as the switching devices, and in one design an output voltage pulse is produced that has a peak amplitude nearly twice that of the supply voltage. The pulsers are inexpensive and relatively easy to construct. The power supply need only provide the average current to charge the capacitors, as opposed to the much higher peak pulse current. With a 1200 V supply and a pulse repetition frequency of 200 Hz, the nondoubling and doubling pulsers provided peak voltages of greater than 1100 V and 2200 V, respectively, into loads ranging from 50 omega to 500 omega. For a 50 omega load, slewing rates of 38 V/ns and 23 V/ns were measured for the nondoubling and doubling pulsers, respectively. For a 500 omega load these values were 56 V/ns and 36 V/ns.

Download full-text PDF

Source
http://dx.doi.org/10.1109/tuffc.2003.1256313DOI Listing

Publication Analysis

Top Keywords

ultrasound measurement
8
measurement applications
8
nondoubling doubling
8
doubling pulsers
8
500 omega
8
omega load
8
v/ns v/ns
8
pulsers
5
igbt-based kilovoltage
4
kilovoltage pulsers
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!