A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single drop microextraction or solid phase microextraction-gas chromatography-mass spectrometry for the determination of iodine in pharmaceuticals, iodized salt, milk powder and vegetables involving conversion into 4-iodo-N,N-dimethylaniline. | LitMetric

A rapid sequence of oxidation and iodination using 2-iodosobenzoate as an oxidizing agent and N,N-dimethylaniline as an iodine scavenger at pH 6.4, when 4-iodo-N,N-dimethylaniline is formed, has been used for the determination of iodide by GC-MS. Solid phase microextraction (SPME) and single drop microextraction (SDME) have been used for the extraction of the iodo-derivative and their relative efficiencies compared. Pharmaceutical samples were subjected to solid phase extraction (SPE) for cleanup and the eluate analyzed for iodide. Iodate in salt samples was reduced to iodide with ascorbic acid. Milk powder and dried vegetables were wet combusted with peroxydisulfate to liberate covalently bound iodine as iodate which was reduced before derivatization. A rectilinear calibration graph was obtained for 0.1 microg-10 mg l(-1) iodide by both extraction methods, the correlation coefficient and limit of detection (LOD) were 0.9995 and 25 ng l(-1) iodide by SPME method, and 0.9998 and 10 ng l(-1) iodide by SDME method, respectively. SDME appeared to be more efficient technique than SPME for the present system. From the pooled data, the average recovery of spiked iodide to real samples was 100.7% (range 96.5-107.0%) with an average R.S.D. of 3.1% (range 2.6-4.5%).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2003.09.056DOI Listing

Publication Analysis

Top Keywords

solid phase
12
l-1 iodide
12
single drop
8
drop microextraction
8
milk powder
8
iodide
7
microextraction solid
4
phase microextraction-gas
4
microextraction-gas chromatography-mass
4
chromatography-mass spectrometry
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!