Aortobifemoral bypass is the standard method for revascularization of aortoiliac occlusive disease but is associated with significant morbidity and mortality. Laparoscopic aortic reconstruction eliminates the large incision but is limited by the cumbersome nature of laparoscopic instrumentation. A robotic system (da Vinci Computer-Enhanced Robotic Surgical System, Intuitive Surgical, Mountain View, CA) has been developed that allows the surgeon to suture in the same manner as in open procedures. The authors report the first case of an aortic reconstruction for occlusive disease performed using the da Vinci system. A 53-year-old woman presented with gangrene of the left great toe. Angiography revealed distal aortic occlusive disease and occlusion of the common iliac arteries bilaterally. Dissection of the aorta was performed by a transabdominal-retroperitoneal approach modified from Dion (J Vasc Surg 26:128-132, 1997). With use of laparoscopic techniques, the abdominal contents were retracted to the patient's right side while the kidney and ureter remained in the retroperitoneum. The aorta was isolated from the bifurcation proximally to the left renal vein. The patient was anticoagulated, and the aorta was clamped below the left renal artery and proximal to the bifurcation. The da Vinci robotic system was placed on the patient's right side, and an extruded polytetrafluoroethylene (ePTFE) graft was passed into the retroperitoneum. While seated at a computer console viewing the operative field on a screen, the surgeon used robotic instruments to fashion an arteriotomy and complete an end-to-side aortic anastomosis using ePTFE suture. The left groin was opened and the aortic graft passed down to the groin. The reconstruction was completed by performing a left-to-right femoro-femoral bypass in standard, open fashion. The procedure was completed in 8 hours with an aortic clamp time of 65 minutes and a 500 cc blood loss. The patient was extubated in the operating room, ate a regular diet on postoperative day 2, and was discharged on postoperative day 4 without complications. Return to normal activities occurred 2.5 weeks postoperatively. The da Vinci robotic system facilitated creation of the aortic anastomosis and shortened aortic clamp time over that achieved with laparoscopic techniques. Robot-assisted laparoscopic aortofemoral bypass should decrease the morbidity and mortality of aortic reconstruction, while providing a durable solution to aortoiliac occlusive disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/153857440403800111 | DOI Listing |
Eur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Vet Radiol Ultrasound
January 2025
AniCura Istituto Veterinario Novara, Monticello, Italy.
With the advancement in imaging technology, ECG-gated cardiac multidetector computed tomography (MDCT) has emerged as a tool for the anatomic evaluation of the pulmonary valve and right ventricular outflow tract (RVOT) in human medicine. Currently, the evaluation of the pulmonary valve relies primarily on echocardiographic examination. However, the bi-dimensional nature of this technique and the location/orientation of the pulmonary valve in the thoracic cavity can pose challenges.
View Article and Find Full Text PDFPort J Card Thorac Vasc Surg
October 2024
Department of Vascular and Endovascular Surgery, St Francis Hospital & Heart Center, Roslyn, NY, USA.
The optimal management of acute type A aortic dissection (ATAAD) remains a controversial subject. While some surgeons opt for a hemiarch approach to minimize bypass and cross-clamping time, others prefer partial or total arch replacement to prevent the need for additional operations. The advent of hybrid approaches offers a variety of options to the aortic surgeon in treating ATAAD.
View Article and Find Full Text PDFVascular
January 2025
Department of Vascular Surgery, Miller Family Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.
Objective: Superior vena cava syndrome (SVC) is a debilitating disease, and surgical reconstruction has been described with some of the best results using spiral great saphenous vein (SGSV) grafts. SGSV grafts can be difficult to construct, and a long segment of saphenous vein is needed. Femoral vein has been an excellent conduit for infected aortic and peripheral reconstructions in our hands, and we sought to review outcomes using this conduit for SVC reconstruction.
View Article and Find Full Text PDFMedicine (Baltimore)
November 2024
Department of Vascular Surgery, the Second Affiliated Hospital, Jiangxi Medical College, Nanchang University.
Stanford type B aortic dissection involving the left subclavian artery (LSA) poses significant clinical challenges. The Castor single-branch stent graft and in situ fenestration are commonly used techniques, but the better endovascular treatment remains debated. This study evaluates the clinical effects of the Castor single-branched stent graft versus in situ fenestration in treating Stanford type B aortic dissection involving the LSA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!