Although dry powder inhalers are well established for the delivery of corticosteroids, the pressurised metered dose inhaler remains the preferred and most cost effective presentation. To design an HFA solution formulation which matched marketed CFC products (Pulmicort and Desonac DA) two elements of the Chiesi Modulite system, the addition of a non-volatile component and the actuator orifice diameter, were varied. These variables, which were shown by in vitro tests to influence the fine particle dose and its mean particle size in different ways, could be permuted to give an aerosol cloud with size characteristics very close to the comparator products. The likelihood that this would confer clinical equivalence is reinforced by a pharmacokinetic analysis which showed that the chosen HFA solution formula gave similar systemic absorption from the lung as Pulmicort. The equivalence in aerosol characteristics was sustained when the pressurised metered dose inhalers (pMDIs) were used with spacers. The Chiesi Jet and the AstraZeneca Nebuhaler, when used with their respective pMDIs, reduced likely oropharyngeal deposition to the same extent and gave a similar increase in the fine particle dose.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.rmed.2003.10.003 | DOI Listing |
Front Bioeng Biotechnol
January 2025
Department of Physical Education, Tsinghua University, Beijing, China.
Purpose: Plantar soft tissue properties affect foot biomechanics during movement. This study aims to explore the relationship between plantar pressure features and soft tissue stiffness through interpretable neural network model. The findings could inform orthotic insole design.
View Article and Find Full Text PDFWater Res X
December 2024
Professor, Department of Civil and Architectural Engineering and Mechanics, The University of Arizona, Tucson, AZ 85721, USA.
Smart meters such as advanced metering infrastructure (AMI) can significantly improve identifying realistic sized leaks in water distribution networks (WDNs). However, to date, detection/localization methods for AMI systems are extremely limited. In this study, to examine the benefits of using AMIs for leak detection within distribution network, a three-dimensional (3D) convolutional neural network (CNN) deep learning (DL) model is proposed that can account for temporally and spatially distributed information of pressures.
View Article and Find Full Text PDFUndersea Hyperb Med
January 2025
Department of Diving and Hyperbaric Medicine, Naval Medical Center, Naval Medical University, Shanghai, P.R. China.
Decompression after diving may inevitably cause the production of bubbles in the body, even without protocol violation. Bubbles produced in the circulation may damage the vascular cells, leading to vascular dysfunction. In this study, five subjects were recruited and subjected to hyperbaric exposure (15 meters; 100 minutes).
View Article and Find Full Text PDFArch Dis Child
January 2025
Murdoch Children's Research Institute, Parkville, Victoria, Australia.
Objective: The aim of this study was to evaluate the acceptability and feasibility of home-based blood pressure (BP) screening in a group of paediatric patients with known elevated risk of developing hypertension.
Design: Cross-sectional study.
Setting: Specialist outpatient clinic and patient homes.
Sci Prog
January 2025
Department of Trauma and Orthopaedics, NHS Grampian, Aberdeen, UK.
Objective: In this feasibility study, firstly, we aimed to assess whether intramuscular pH (IMpH) could be measured with a glass-tipped electrode. Secondly, we aimed to explore whether we could monitor changes in skeletal muscle pH before and throughout static (isometric) and after dynamic (treadmill) exercise, comparing individuals with intermittent claudication (IC) to a group of healthy controls.
Methods: Forty participants with IC (mean age ± SD) 68 ± 8) and 40 healthy volunteers (63 ± 10) were recruited.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!