Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation.

J Hand Surg Am

Department of Orthopaedic Surgery, Washington University School of Medicine at Barnes-Jewish Hospital, Suite 11300 West Pavilion, One Barnes Jewish Hospital Plaza, St Louis, MO 63110, USA.

Published: January 2004

AI Article Synopsis

  • The study aimed to evaluate the effectiveness of anatomic tilt radiographs compared to standard PA and lateral radiographs in detecting screw penetration in the distal radius articular surface.
  • Twenty-four cadaver forearm specimens were assessed using different radiographic views, and results showed that anatomic tilt views significantly enhanced accuracy, sensitivity, and specificity for detecting screw penetration.
  • The findings indicate that using anatomic tilt views can lead to higher accuracy and confidence among observers in identifying the position of the penetrated screws, making them a valuable tool in clinical practice.

Article Abstract

Purpose: To compare anatomic tilt radiographs with standard posteroanterior (PA) and lateral radiographs for their efficacy in detecting screw penetration of the distal radius articular surface.

Methods: Twenty-four cadaveric human forearm specimens had fixation with a dorsal distal radius plate and screws. Three groups were evaluated: (1) no articular surface screw penetration, (2) radial-sided articular screw penetration, and (3) ulnar-sided articular screw penetration. Standard PA and lateral views and anatomic tilt PA and lateral views were taken of each specimen. Three observers reviewed both individual (PA or lateral) and paired (PA and lateral) radiographs. These radiographs were evaluated based on whether or not articular penetration had occurred. A number between 1 and 5 was assigned to represent the degree of certainty of their assessment. The accuracy of the observers was calculated to determine if screw penetration of the articular surface had occurred and, if so, which screw had penetrated the joint. The sensitivity and specificity of each view, interobserver reliability, and the reviewers' confidence in evaluating presence or absence of screw penetration were calculated.

Results: The use of anatomic tilt lateral views significantly improved the overall accuracy, (0.93 vs 0.64), sensitivity (0.98 vs 0.77), and specificity (0.83 vs 0.38) of the detection of articular screw penetration when compared with standard lateral views. PA and lateral anatomic tilt views, when viewed together, significantly improved (p <.001) the accuracy of each observer's determination of the position of the penetrated screw (0.90 vs 0.67). In addition, anatomic tilt views significantly improved the confidence of the reviewers in their more accurate observations (4.7 vs 3.3, p <.05).

Conclusions: Anatomic tilt PA and lateral radiographs of the distal radius are an accurate and clinically useful tool for the evaluation of both presence and location of screw penetration of the articular surface after dorsal plating.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2003.09.004DOI Listing

Publication Analysis

Top Keywords

screw penetration
28
anatomic tilt
20
lateral views
16
distal radius
12
articular screw
12
lateral
8
lateral radiographs
8
screw
8
penetration
8
articular surface
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!