Six-hundred and twenty-six stool specimens collected from children with diarrhea over a 12-month period were tested for rotavirus using a real time reverse transcription-polymerase chain reaction (RT-PCR) assay, a conventional nested PCR assay and by electron microscopy (EM). A fragment of 87 bp in a highly-conserved region of non-structural protein 3 (NSP3) in rotavirus genome was amplified by a single-step RT-PCR protocol in a closed-tube system. Rotavirus was detected in 123 samples (20%) with the real time RT-PCR assay, 113 samples (18%) with the nested-PCR assay, and 79 samples (13%) with EM. Using serial diluted nucleic acid extract, we compared the sensitivity of real time RT-PCR with conventional RT-PCR and conventional nested PCR assays. Real time RT-PCR was two to four logs more sensitive than the conventional assays. The reaction time required for the RT-PCR assay is about half the time required for the conventional nested-PCR. The real time RT-PCR assay is both simple and rapid with advantages including enhanced sensitivity and a lower risk for cross-contamination making it a useful tool for the detection of rotavirus in various situations including sporadic gastroenteritis, outbreaks, and environmental investigations. G(1) was the predominant type (89%), followed by G(2) (10%), and G(4) (1%). No rotavirus of G(3), G(8), and G(9) types were found. The peak season for rotavirus infection was January to May in northern Alberta.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jmv.20009 | DOI Listing |
Mol Neurobiol
January 2025
Department of Anesthesiology, Yijishan Hospital, First Affiliated Hospital of Wannan Medical College, Wuhu, 241004, China.
Stroke is the second-leading global cause of death. The damage attributed to the immune storm triggered by ischemia-reperfusion injury (IRI) post-stroke is substantial. However, data on the transcriptomic dynamics of pyroptosis in IRI are limited.
View Article and Find Full Text PDFJ Fluoresc
January 2025
Department of Fine Chemistry, Seoul National University of Science and Technology, Seoul, 01811, Korea.
We report a bithiophene-based fluorescence probe BDT (2,2'-(((1 E, 1'E)-[2,2'-bithiophene]-5,5'-diylbis(methaneylylidene))bis(azaneylylidene))bis(4-(tert-butyl)phenol)) for recognizing ClO. BDT selectively responded to ClO, leading to a blue fluorescence enhancement in a mixture of DMF/HEPES buffer (9:1, v/v). Importantly, BDT showed an ultrafast response (within 1 s) to ClO among the fluorescent turn-on chemosensors based on bithiophene.
View Article and Find Full Text PDFClin Drug Investig
January 2025
Department of Medicine, Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Perelman School of Medicine, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
Purpose: The REDUCE-IT randomized trial demonstrated a cardiovascular benefit of icosapent ethyl (IPE) but also raised potential safety signals for atrial fibrillation (AF) and serious bleeding. We aimed to evaluate the real-world safety of IPE versus mixed omega-3 polyunsaturated fatty acid (OM-3) formulations.
Methods: This retrospective active comparator new-user cohort study compared rates of new-onset AF and major bleeding (MB) among adult new users of IPE versus OM-3 in 2020-2024 US Veterans Affairs data.
JACC Clin Electrophysiol
December 2024
Physiology, Amsterdam Cardiovascular Sciences, Heart Failure, and Arrhythmias, Amsterdam University Medical Center, location Vrije Universiteit Amsterdam, Amsterdam, the Netherlands. Electronic address:
Background: Atrial fibrillation (AF) persistence is associated with molecular remodeling that fuels electrical conduction abnormalities in atrial tissue. Previous research revealed DNA damage as a molecular driver of AF.
Objectives: This study sought to explore the diagnostic value of DNA damage in atrial tissue and blood samples as an indicator of the prevalence of electrical conduction abnormalities and stage of AF.
J Vet Intern Med
January 2025
Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA.
Background: Left ventricular (LV) volumes can be calculated from various linear, monoplane, and multiplane echocardiographic methods, and the same method can be applied to different imaging views. However, these methods and their variations have not been comprehensively evaluated against real-time 3-dimensional echocardiography (RT3D).
Hypothesis/objectives: To identify the LV volumetric approaches that produce the least bias and the best agreement with RT3D, and to assess interoperator reproducibility between an experienced and an inexperienced operator.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!