Aim: The aim of this study was to determine the effects of vacuum extractor assisted delivery on fetal oxygenation and acid-base balance.
Methods: Sixty-one women were enrolled in the present study. The subjects were divided into two groups. Group A, consisting of 39 women, had normal vaginal deliveries. Group B, consisting of 22 women, underwent a vacuum extractor assisted vaginal delivery. Fetal arterial oxygen saturation (SpO2) monitoring was used in all women after full cervical dilatation. After delivery, umbilical artery pH, pCO2, pO2 and base deficit (BDecf) levels were determined in all neonates.
Results: The mean FSpO2 value in Group A was 51.53+/-5.87% and in Group B 48.03+/-6.39% (p<0.03). The mean cord pH value in fetuses of Group A was 7.26+/-0.05, and in Group B 7.17+/-0.09. There was also a significant difference between the two groups with regards to mean pO2, pCO2 and BDecf values.
Conclusions: Vacuum assisted vaginal delivery was associated with lower fetal arterial oxygen saturation levels as well as lower cord blood pH values compared to those seen after unassisted vaginal delivery. Although decreased, however, the above parameters remained within normal ranges.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00404-003-0598-2 | DOI Listing |
Am J Forensic Med Pathol
November 2024
Neonatology Unit, IRCCS-Ospedale Policlinico San Martino Teaching Hospital, Genova, Italy.
In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures.
View Article and Find Full Text PDFACS Omega
June 2024
Optical Physics Division, Corning Research and Development, Sullivan Park, Corning, New York 14831, United States.
Extracting photons efficiently from quantum sources, such as atoms, molecules, and quantum dots, is crucial for various nanophotonic systems used in quantum communication, sensing, and computation. To improve the performance of these systems, it is not only necessary to provide an environment that maximizes the number of optical modes, but it is also desirable to guide the extracted light toward specific directions. One way to achieve this goal is to use a large area metasurface that can steer the beam.
View Article and Find Full Text PDFChilds Nerv Syst
April 2024
Department of Neurosurgery, Universidade Federal de São Paulo, Rua Napoleão de Barros 715, 6th Floor, 04024-002, São Paulo, SP, Brazil.
Purpose: The management of depressed skull fractures in infants can be either conservative or surgical. This study aimed to examine the outcomes of management with a negative-pressure vacuum device on depressed skull fractures in newborns.
Methods: Twenty-eight patients (aged 1-6 days) with simple depressed skull fractures underwent skull elevation using negative-pressure vacuum devices.
MethodsX
December 2023
Tokyo University of Marine Science and Technology, 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan.
For the detection of microplastics (MPs) in aquatic biota using Fourier transform infrared spectroscopy (FTIR), the ability to remove organic matter (OM) in pretreatment steps is essential to increase the time efficiency of MPs measurement and method uniformity. In principle, decreasing OM can be achieved by increasing the number of pretreatment steps. However, MPs are lost in proportion to the number of transfers between each step.
View Article and Find Full Text PDFJ Endourol
December 2023
Department of Urology, The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Percutaneous nephrolithotomy (PCNL) is the recommended treatment for 2-4-cm renal stones. Minimally invasive PCNL (MPCNL) with ≤22F sheath was frequently used instead of standard PCNL. MPCNL uses pressurized irrigation to flush out stone fragments through a conventional nephrostomy sheath (cNS), which may result in higher intrarenal pressure (IRP) and longer operating time.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!