A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detecting early to mild glaucomatous damage: a comparison of the multifocal VEP and automated perimetry. | LitMetric

AI Article Synopsis

  • The study aims to understand how well multifocal visual evoked potentials (mfVEP) align with traditional visual field tests in patients with glaucoma.
  • Fifty patients with open-angle glaucoma underwent both mfVEP and automated visual field testing, focusing on specific criteria for glaucomatous damage.
  • Results showed a 74% agreement between the two tests on identifying abnormalities, but discrepancies were noted, with mfVEP detecting more issues in some cases and visual field tests missing others.

Article Abstract

Purpose: To gain better understanding of the relationship between abnormalities detected by the multifocal VEP (mfVEP) compared with those detected by static achromatic, automated perimetry in patients with glaucoma.

Methods: Fifty patients were studied who had open-angle glaucoma that met the following criteria: (1) a mean deviation (MD) of better than -8 dB in both eyes on the 24-2 Humphrey visual field (HVF) test (Carl Zeiss Meditec, Dublin, CA); and (2) glaucomatous damage in at least one eye, as defined by a glaucomatous optic disc and an abnormal 24-2 HVF test result (pattern standard deviation [PSD] <5% and/or glaucoma hemifield test [GHT] results outside normal limits). Monocular mfVEPs were obtained from each eye by using a pattern-reversal dartboard array, 44.5 degrees in diameter, which contained 60 sectors. Recording electrodes were placed at the inion (I) and I+4 cm, and also at two lateral locations up 1 cm and over 4 cm from I. Monocular and interocular mfVEP probability plots were derived by comparing the results with those of normal control subjects. For both the HVF and mfVEP probability plots, a hemifield was classified as abnormal if three or more contiguous points were significant at less than 5%, with at least one at less than 1%.

Results: Of the 200 hemifields tested (50 patients x two eyes x two hemifields), 75 showed significant clusters on the HVF, and 74 (monocular probability plot) and 93 (monocular or interocular plot) showed significant clusters on the mfVEP. Overall, the HVF and mfVEP results agreed on 74% of the hemifields, and 90 hemifields were normal and 58 were abnormal on both the mfVEP (interocular and/or monocular abnormal) and HVF cluster tests. Of the 52 disagreements, 35 hemifields had a significant cluster on the mfVEP, but not on the HVF, whereas the reverse was true of 17 hemifields. A case-by-case analysis indicated that misses and false-positive results occurred on both the HVF and mfVEP tests.

Conclusions: As predicted from a theoretical analysis, under these conditions (i.e., the signal-to-noise level) the HVF and monocular mfVEP tests showed a comparable number of defects, and, with the addition of the interocular test, the mfVEP showed more abnormalities than the HVF. However, although there were abnormalities detected by the mfVEP that were missed by the HVF, the reverse was true as well.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.03-0602DOI Listing

Publication Analysis

Top Keywords

glaucomatous damage
8
multifocal vep
8
automated perimetry
8
hvf test
8
detecting early
4
early mild
4
mild glaucomatous
4
damage comparison
4
comparison multifocal
4
vep automated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!