The simplified generalized standard additions method (GSAM) was investigated as an alternative method for the ICP-OES analysis of solid materials, introduced into the plasma in the form of slurries. The method is an expansion of the conventional standard additions method. It is based on the principle of varying both the sample mass and the amount of standard solution added. The relationship between the sample mass, standard solution added and signal intensity is assumed to be linear. Concentration of the analyte can be found either geometrically from the slope of the two-dimensional response plane in a three-dimensional space or mathematically from the ratio of the parameters estimated by multiple linear regression. The analysis of a series of certified reference materials (CRMs) (cement CRM-BCS No 353, gypsum CRM-Gyp A and basic slag CRM No 382/I) introduced into the plasma in the form of slurry is described. The slurries contained glycerol and hydrochloric acid and were placed in an ultrasonic bath to ensure good dispersion. "Table curve 3D" software was used to fit the data. Results obtained showed that the method could be successfully applied to the analysis of cement, gypsum and slag samples, without the need to dissolve them. In this way, we could avoid the use of hazardous chemicals (concentrated acids), incomplete dissolution and loss of some volatiles. The application of the simplified GSAM for the analysis did not require a CRM with similar chemical and mineralogical properties for the calibration of the instrument.