Background And Objective: A newly developed radio-frequency monopolar needle electrode was evaluated in vitro on porcine tongues.
Patients And Methods: Porcine tongues with different tissue temperatures (20+/-1) degrees C and (32+/-2) degrees C were coagulated for 90 s. In a second step, 23 coagulations at 7 W were applied (34+/-2) degrees C.
Results: The volume of the lesion correlated well with increasing temperature. In step two, the mean energy was 238 J and the mean volume of the lesion was 507 mm(3) (100+/-15)%. Prolonged energy application did not correlate with a larger volume of the lesion.
Conclusion: The new radio-frequency needle electrode can reduce tongue volume in a precise and controlled manner (SD+/-15%).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00106-003-0853-7 | DOI Listing |
Bioact Mater
April 2025
Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, PR China.
Bioelectrical stimulation is a powerful technique used to promote tissue regeneration, but it can be hindered by an "electrical overload" phenomenon in the core region of stimulation. We develop a threaded microneedle electrode system that protects against "electrical overload" by delivering medicinal hydrogel microspheres into the core regions. The threaded needle body is coated with polydopamine and chitosan to enhance the adhesion of microspheres, which are loaded into the threaded grooves, allowing for their stereoscopic release in the core regions.
View Article and Find Full Text PDFJ Vis Exp
January 2025
School of Acupuncture-Moxibustion and Tuina, Beijing University of Chinese Medicine;
Electroacupuncture (EA) is one of the most commonly used methods in acupuncture and has a good effect on pain, depression, sensory movement disorders, and other diseases. The effectiveness of EA is influenced by many factors, such as the accuracy of acupoint selection, the duration and course of EA treatment, and EA parameters. However, it has rarely been discussed whether the positive and negative electrodes of the EA instrument with acupoints at different locations and distances have an effect on the curative effect.
View Article and Find Full Text PDFTissue Eng Regen Med
January 2025
College of Materials Science and Engineering, Hunan University, Changsha, 410072, People's Republic of China.
Background: Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
Methods: A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring.
J Electromyogr Kinesiol
January 2025
Hacettepe University, Faculty of Medicine, Department of Neurology, Ankara, Turkey.
Objectives: Jitter analysis with concentric needle electrode of the thoracic 9 (T9) paraspinal muscle (PM), where the needle EMG examination at rest is difficult, was performed in both amyotrophic lateral sclerosis (ALS) patients and the controls.
Methods: For the T9 PM, both upper limit for mean and individual mean consecutive difference (MCD) values and spike numbers were calculated according to jitter values of pairs from controls. In addition to the descriptive statistics, differences between two groups and T9 PM needle EMG and jitter analysis findings of patients were compared (p = 0.
Sci Rep
January 2025
National Research Centre, Geophysical Sciences Department, Geophysical Exploration Lab., Dokki, Cairo, Egypt.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!