  • The study assessed the reliability and validity of different methods for measuring urine specific gravity in collegiate wrestlers, focusing on refractometry, hydrometry, and reagent strips.
  • Refractometry showed high consistency both between trials and among testers, while hydrometry was reliable in trials but inconsistent among testers; reagent strips were unreliable overall.
  • The study concluded that only refractometry is suitable for determining urine specific gravity during the weight-certification process for wrestlers.

Article Abstract

OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC314390PMC

Publication Analysis

Top Keywords

reagent strips
24
specific gravity
20
urine specific
16
collegiate wrestlers
16
refractometry hydrometry
16
hydrometry reagent
16
gravity collegiate
12
measurements consistent
12
consistent trials
12
trials testers
8

Similar Publications

Detection of Hydrogen Peroxide Vapors Using Acidified Titanium(IV)-Based Test Strips.

Materials (Basel)

December 2024

Department of Chemistry, 316 Physical Science, Oklahoma State University, Stillwater, OK 74078, USA.

One method for the colorimetric detection of hydrogen peroxide vapor is based on a titanium-hydrogen peroxide complex. A color changing material based on a titania hydroxypropyl cellulose thin film was initially developed. However, as this material dries, the sensitivity of the material is significantly reduced.

View Article and Find Full Text PDF

A Multifunctional Tb(III)-Based Metal-Organic Framework for Chemical Conversion of CO, Fluorescence Sensing of Trace Water and Metamitron.

Inorg Chem

December 2024

School of Materials Science and Chemical Engineering, Resource Recycling of Ningbo University - Ningbo Shuangneng Environmental Technology Co., Ltd., Ningbo University, Ningbo 315211, China.

The utilization of metal-organic frameworks (MOFs) as fluorescent sensors for the detection of environmental and chemical reagent pollutants as well as heterogeneous catalysis for CO conversion represents a crucial avenue of research with significant implications for the protection of human health. In this work, a Tb(III)-based three-dimensional metal-organic framework, [Tb(L)·4DMF] (Tb-MOF) (HL = 5'-(4-carboxy-3-hydroxyphenyl)-3,3″-dihydroxy-[1,1':3',1″-terphenyl]-4,4″-dicarboxylic acid), has been structurally conformed by single-crystal X-ray crystallography. It possesses a 1D rhombus channel along the [010] direction, featuring a pore size of 6.

View Article and Find Full Text PDF

Affordable paper-based strips: A breakthrough in phenol detection for water samples.

Spectrochim Acta A Mol Biomol Spectrosc

March 2025

Graduate School of Integrated Energy-AI, Jeonbuk National University, Jeonju 54896, the Republic of Korea. Electronic address:

Article Synopsis
  • Phenols are common industrial pollutants found in sectors like pharmaceuticals and agriculture, often released untreated, necessitating effective detection methods.
  • Current detection techniques like spectrophotometry and chromatography are costly and complex, highlighting the need for a simpler, affordable solution.
  • This study presents a new method using low-cost colorimetric paper-based sensor strips to detect phenols in water using the Folin-Ciocalteu reagent, achieving high recovery rates with promising detection limits.
View Article and Find Full Text PDF

A novel triple signal amplification platform of peroxide test strip for sensitive detection of adenosine triphosphate.

Talanta

March 2025

Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, China. Electronic address:

Peroxide test strip (PTS) has been widely used for the point-of-care testing (POCT), but its poor sensitivity is a big obstacle for analyzing trace target. Herein, a triple signal amplifying platform integrating the liposome enrichment, the hybridization chain reaction (HCR) circuit, and the image analysis method was constructed to enhance the visual readout of PTS for the sensitive detection of adenosine triphosphate (ATP), an important biomarker of food spoilage. In the presence of ATP, the HCR amplifier was firstly initiated on the surface of magnetic beads (MBs), inducing a large number of glucose oxidase (GOD) imbedded liposomes to be attached.

View Article and Find Full Text PDF

Porcine epidemic diarrhea virus (PEDV) causes severe enteric disease and high mortality in neonatal piglets, leading to significant economic losses in the swine industry. Considering that passive lactogenic immunity is crucial for preventing infection in piglets, necessitating a rapid and accurate tool to measure immunity levels. This study aims to develop a lateral flow immunochromatographic strip (LFICS) to assess IgA and IgG antibodies in colostrum and milk, using PEDV S protein.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!