Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Modern, thrust-vectored jet aircraft have the capability of developing multi-axis accelerations, especially during the performance of "supermaneuvers." These "agile" aircraft are capable of unconventional flight. The human consequences of this agile flight environment are unknown.
Methods: This multi-axis acceleration environment was studied on the Dynamic Environment Simulator gimbaled centrifuge. There were nine relaxed, unprotected subjects who were exposed to either lateral (+/- 1, +/- 2 Gy), transverse chest-to-back (+1, 2.5, or 4 Gx), or back-to-chest (-1 Gx) sustained acceleration. Positive C (+Gz) acceleration was then added beginning at 1.0 Gz by gradual onset (0.1 Gz x s(-1)) until the subjects lost nearly all of their vision. Baseline +Gz-only relaxed tolerances were measured before and after all combined Gy/Gz and Gx/Gz exposures. Heart rate, percent cerebral oxygen saturation, and cerebral blood volumes were collected during each exposure.
Results: Adding moderate transverse (+Gx) acceleration significantly reduced +Gz tolerance. Relaxed, unprotected +Gz tolerance was reduced approximately 0.25 G when 1.0 or 2.5 Gx was added to the increasing +Gz exposure. Adding moderate lateral Gy significantly increased +Gz tolerance. Relaxed, unprotected +Gz tolerance was increased approximately 0.5 G when +2 Gy or -2 Gy was added to the -Gz exposure. The decrease in cerebral blood volume was significantly less when +Gz was added to -1 Gx compared with the addition of +Gz to +Gx.
Conclusions: Multi-axis sustained accelerations, such as those experienced during thrust-vectored aircraft maneuvers, can either enhance or reduce the +Gz tolerance of the pilot depending on the direction of the net gravitoinertial force. Gy acceleration in conjunction with Gz acceleration can enhance G tolerance. Gx acceleration in addition to Gz acceleration can reduce G tolerance.