A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

When good water goes bad: how it happens, clinical consequences and possible solutions. | LitMetric

When good water goes bad: how it happens, clinical consequences and possible solutions.

Blood Purif

Gemeinschaftspraxis Nephrology/Dialysis, Langenhagen, Germany.

Published: September 2004

Dialysis fluid produced by state-of-the-art water preparation and distribution is contaminated with gram-negative bacteria and cytokine-inducing substances (CIS) derived from these microorganisms. The presence of a biofilm increases the risk of continuous contamination of dialysis fluid. Depending on the type of dialyzer membrane (cellulosic vs. synthetic) and the mode of dialysis (low flux vs. high flux with backfiltration), CIS may penetrate intact dialyzer membranes, induce cytokine production in the patient's blood and contribute to chronic inflammation associated with long-term hemodialysis therapy. Measures to improve the microbiological quality of dialysis fluid are: (1) the awareness of the problem and regular testing of dialysate samples using adequate methods; (2) disinfection of the entire water preparation and distribution system on a regular basis, replacement of biofilm-containing tubings, and (3) installation of ultrafilters in the dialysate circuit in particular when high-flux hemodialysis modalities are performed.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000074932DOI Listing

Publication Analysis

Top Keywords

dialysis fluid
12
water preparation
8
preparation distribution
8
good water
4
water bad
4
bad clinical
4
clinical consequences
4
consequences solutions
4
dialysis
4
solutions dialysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!