A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

EEG quality during simultaneous functional MRI of interictal epileptiform discharges. | LitMetric

EEG quality during simultaneous functional MRI of interictal epileptiform discharges.

Magn Reson Imaging

Department of Clinical and Experimental Epilepsy, Institute of Neurology, University College London, Queen Square, London, UK.

Published: December 2003

This article concerns the evaluation of the quality of interictal epileptiform EEG discharges recorded throughout simultaneous echo planar imaging (EPI). BOLD (blood oxygen level dependent) functional MRI (fMRI) images were acquired continuously on a patient with intractable epilepsy. EEG was sampled simultaneously, during and after imaging, with removal of pulse and imaging artifacts by subtraction of channel-specific running averages. Contiguous EEG epochs recorded with and without fMRI (fMRI+ve vs. fMRI-ve) were next randomized and presented to two blinded observers. Epileptiform discharges were identified retrospectively, and comparison was made in terms of the number of identified events, their amplitude, and spatiotemporal distribution. A spectral analysis was also performed on the EEG. In the randomized comparison of EEG segments, 80 (fMRI+ve) vs. 69 (fMRI-ve) discharges were noted with good interobserver agreement (69%). There were no significant differences in amplitude or spatio-temporal distribution. Comparison of the events detected and measured by two expert observers demonstrated that the Interictal Epileptiform Discharge (IED) characteristics were indistinguishable with and without scanning. We review briefly the existing literature on EEG recording quality for combined EEG/fMRI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2003.08.017DOI Listing

Publication Analysis

Top Keywords

interictal epileptiform
12
functional mri
8
epileptiform discharges
8
fmri+ve fmri-ve
8
eeg
7
eeg quality
4
quality simultaneous
4
simultaneous functional
4
mri interictal
4
epileptiform
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!