Background & Aims: In the United States, upper gastrointestinal endoscopy is usually performed using intravenous sedation. Sedation increases the rate of both complications and costs of endoscopy. Unsedated esophagogastroduodenoscopy (EGD) using conventional 8-11-mm endoscopes is an alternative to sedated endoscopy but is generally perceived as unacceptable to many American patients. Unsedated EGD using ultrathin 5-6-mm endoscopes is better tolerated. A randomized trial comparing unsedated ultrathin EGD (UT-EGD) with sedated conventional EGD (C-EGD) in a diverse American population is needed.
Methods: In this multicenter, randomized, controlled trial, 80 patients scheduled to undergo elective outpatient EGD were randomized to unsedated UT-EGD or sedated C-EGD. The study was carried out at San Francisco General Hospital, San Francisco Veterans Affairs Medical Center, and the Liver and Digestive Health Medical Clinic, San Jose.
Results: Baseline characteristics of patients randomized to unsedated UT-EGD and sedated C-EGD were similar. Moreover, there were no significant differences in overall patient satisfaction and willingness to repeat endoscopy in the same manner among the 2 study groups. There was, however, a significant difference in median total procedure time between the 2 study groups of 1.5 hours (P < 0.0001). The mean (+/- SD) total procedure cost was 512.4 US dollars (+/- 100.8 US dollars) for sedated C-EGD and 328.6 US dollars (+/- 70.3 US dollars) for unsedated UT-EGD (P < 0.0001).
Conclusions: Patients undergoing unsedated UT-EGD are as satisfied as patients undergoing sedated C-EGD and are just as willing to repeat an unsedated UT-EGD. Unsedated UT-EGD was also faster, less costly, and may allow greater accessibility to this procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/j.gastro.2003.08.034 | DOI Listing |
Gastrointest Endosc
January 2024
Department of Gastroenterology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Background And Aims: Ultrathin EGD (UT-EGD) is an ideal tool for unsedated upper GI examination and pediatric gastroenterology but is rarely competent for EUS miniprobe (EUS-MP). We developed a UT-EGD US method (UT-EUS) and verified its clinical application value through animal experiments.
Methods: Five Bama miniature pigs were selected.
J Gastroenterol Hepatol
December 2017
Division of Gastroenterology, Department of Internal Medicine, Buddhist Tzu Chi General Hospital and Tzu Chi University, Hualien, Taiwan.
Background And Aim: Sniff test is a common method before unsedated transnasal esophago-gastro-duodenoscopy (UT-EGD) to select a nostril insertion site. Yet there is no objective method to select a more specific meatus insertion tract for anesthesia and insertion. We devised an endoscopic meatus scoring scale by anterior meatuscopy to select the most optimal meatus insertion tract.
View Article and Find Full Text PDFEndosc Int Open
December 2015
Division of Gastroenterology, Department of Internal Medicine, Buddhist Tzu Chi General Hospital and Tzu Chi University, Hualien, Taiwan ; Graduate Institute of Clinical Medicine, School of Medicine, Tzu Chi University, Hualien, Taiwan.
Background And Study Aims: Unsedated transnasal esophago-gastro-duodenoscopy (UT-EGD) has been performed for at least two decades but many techniques related to the procedure have yet to be standardized. We aimed to develope a simple endoscopic method, anterior meatuscopy, to replace the sniff test for selecting the most patent nasal meatus before UT-EGD. We hypothesized that access to the common nasal meatus (CNM), if confirmed by anterior meatuscopy, was a safer route than the inferior (INM) and middle nasal meatuses (MNM) because it would result in reduced epistaxis, nasal pain, and nasal discharge.
View Article and Find Full Text PDFAm J Gastroenterol
May 2008
Division of Gastroenterology, Department of Internal Medicine, Buddhist Tzu Chi General Hospital and Tzu Chi University, Hualien, Taiwan.
Background: Ultrathin transnasal esophagogastroduodenoscopy (UT-EGD) is well tolerated by patients, but the methods of nasal anesthesia are various.
Aim: To compare patient tolerance, safety, and adverse events between the endoscopic-guided (EGNA) and cotton-tipped applicator (CTNA) methods of nasal anesthesia.
Methods: Between September 2005 and September 2006, we conducted a prospective, randomized, controlled study in a large tertiary referral hospital in eastern Taiwan.
Gastrointest Endosc
March 2008
Geneva University Hospitals, Geneva, Switzerland.
Background: Training programs in unsedated transnasal (UT) EGD are scarce.
Objective: To prospectively assess the learning curve for unsupervised UT-EGD.
Setting: Endoscopy service, without experience in UT-EGD.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!