We developed a coated tube assay to discriminate TSH-receptor-stimulating autoantibodies [thyroid-stimulating antibodies (TSAb)] from those autoantibodies blocking TSH binding without intrinsic activation [thyroid-blocking antibodies (TBAb)]. The wild-type TSH receptor in the TSH binding-inhibitory assay was exchanged for a chimeric receptor where a TSAb epitope (amino acids 8-165) was replaced by comparable LH-R residues. Binding of (125)I-labeled TSH to this chimera could be inhibited by sera containing TBAb up to 95%. Sera from 316 patients with Graves' disease and 17 with autoimmune thyroid disease were grouped according to their bioassay activity. At the decision threshold, the chimera A assay had a sensitivity of 78.0% for TBAb with a specificity of 90.2%. In detail, 19 of 22 (86.4%) TBAb sera and 15 of 23 (65.2%) TSAb/TBAb sera were positive but only 32 of 216 (14.0%) TSAb sera and 5 of 72 (6.9%) bioassay negative sera. There was a weak but significant positive correlation (r = 0.46) between the chimera assay and the bioassay for TBAb. This is the first report of a coated tube assay for the determination of TBAb employing an adaptation of the TSH binding-inhibitory format, which could be a useful alternative to the bioassay.

Download full-text PDF

Source
http://dx.doi.org/10.1210/jc.2003-030823DOI Listing

Publication Analysis

Top Keywords

coated tube
12
tube assay
12
tsh binding-inhibitory
8
chimera assay
8
assay
6
sera
6
tsh
5
tbab
5
assay detection
4
detection blocking
4

Similar Publications

Introduction: Endotracheal tubes (ETT) are used in patients who require ventilatory support. Colonization of ETTs by microorganisms is associated with developing ventilator-associated pneumonia (VAP). Thus, this meta-analysis aims to compare conventional endotracheal tubes with those made using materials designed to prevent colonization.

View Article and Find Full Text PDF

Solid-phase microextraction (SPME) is a fast and simple sample preparation technique that enables the enrichment of analytes, and it is used in combination with other detection techniques to provide accurate and sensitive analytical methods. SPME is widely used in environmental monitoring, food safety, life analysis, biomedicine, and other applications. The extractive coating is the core of the SPME technique, and the properties of the extractive coating greatly influence extraction selectivity and efficiency, as well as the enrichment effect.

View Article and Find Full Text PDF

A novel, to the best of our knowledge, optical fiber whispering-gallery mode (WGM) sensor for simultaneously measuring humidity and temperature is proposed and investigated. The proposed sensor is realized by a polyvinyl alcohol (PVA)-coated capillary tube coupling with an optical single-mode fiber (SMF), which is integrated with a fiber Bragg grating (FBG). The as-fabricated sensor can be used not only for relative humidity (RH) sensing but also for temperature detection.

View Article and Find Full Text PDF

Detailed Analysis of the Debris-Fretting Damage Areas on Coated Fuel Cladding.

Materials (Basel)

January 2025

Centrum Výzkumu Řež s.r.o., Hlavní 130, 250 68 Husinec-Řež, Czech Republic.

Fuel failure caused by fretting damage to cladding remains a relevant issue despite decades of research and development aimed at enhancing the physical parameters of fuel. This paper presents the results of experiments conducted at the Research Centre Řež on Zr-1%Nb alloy tube specimens covered with protective coatings made of chromium (Cr) and nitrogen (N) compounds. The experiments involved debris-fretting tests under dry conditions at room temperature as well as microscopic measurements of groove depths.

View Article and Find Full Text PDF

Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.

Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!