The Symmetry Bypass Connector (St. Jude Medical, St. Paul, Minnesota) is a nitinol, star-shaped device that was designed to facilitate placement of sutureless aorto-saphenous anastomoses during off-pump coronary artery bypass graft surgery (CABG). Although the device is approved for clinical use in Europe and the U.S., its short- and long-term safety and efficacy are not established. We report on 5 of 121 patients undergoing CABG who presented with an acute coronary syndrome two to five months following placement of this device. In each patient, all saphenous vein grafts (SVGs) placed (n = 11) with the device were totally occluded (n = 6) or compromised by ostial stenoses (n = 5). Treatment consisted of repeat CABG in one patient and percutaneous coronary intervention (PCI) in four patients with cutting balloon atherotomy and stenting. Following PCI, two of four patients presented again within two months with near-occlusive ostial restenosis in all stents placed. Intracoronary ultrasound showed severe neointimal hyperplasia, but only at the proximal interface of the device and stent. One patient was treated with brachytherapy in two SVGs but had a recurrence four months later and was treated with drug-eluting stents in both restenotic segments. Recalcitrant neointimal hyperplasia is postulated to be involved in the pathogenesis of anastomotic device stenosis, possibly similar to in-stent restenosis. Prospective randomized clinical trials are needed to assess the clinical safety and efficacy of this device. Pending such studies, consideration should be given in limiting its use to cases of unacceptably high risk of stroke during aortic cross-clamping. Dual antiplatelet agents, evaluation for ischemia, and close follow-up are warranted in patients that have already received the device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2003.09.028 | DOI Listing |
Lasers Med Sci
January 2025
University of Campinas, Campinas, Brazil.
Purpose: RVVC is defined as four or more episodes of candidiasis in a 12-month period. Conventional treatment is complex and often involves long-term medication use or multiple treatments. ABL therapy is a promising treatment option as it is acceptable to women and has only rare side effects.
View Article and Find Full Text PDFArch Dermatol Res
January 2025
Dermatology and Venereology Department, Faculty of Medicine for Girls, Al-Azhar University, Cairo, Egypt.
Morphea is a chronic inflammatory fibrosing disorder. Since fibrosis is the hallmark of both scars and morphea, our attention was raised for the possible use of Fractional Ablative CO lasers and microneedling as treatment modalities for morphea. To compare the efficacy and safety of Fractional Ablative CO lasers and microneedling in the treatment of morphea.
View Article and Find Full Text PDFCurr Cardiol Rep
January 2025
Pediatric Advanced Heart Failure and Heart Transplant Program, University of Mississippi Medical Center, 2500 N State Street, Jackson, MS, USA.
Purpose Of Review: Traditionally viewed as a passive player in circulation, the right ventricle (RV) has become a pivotal force in hemodynamics. RV failure (RVF) is a recognized complication of primary cardiac and pulmonary vascular disorders and is associated with a poor prognosis. Unlike treatments for left ventricular failure (LVF), strategies such as adrenoceptor signaling inhibition and renin-angiotensin system modulation have shown limited success in RVF.
View Article and Find Full Text PDFLangenbecks Arch Surg
January 2025
Department of Trauma Surgery, University Hospital Zurich, Rämistrasse 100, CH - 8091, Zurich, Switzerland.
Introduction: Blunt traumatic aortic injury (TAI) is a critical condition and a leading cause of mortality in trauma patients, often resulting from high-speed accidents. Thoracic endovascular aortic repair (TEVAR) has developed into the preferred therapeutic approach due to its minimally invasive nature and promising outcomes. This study evaluates the safety and efficacy of TEVAR for managing TAI over a 10-year period at a Level-1 trauma center.
View Article and Find Full Text PDFJ Mol Model
January 2025
Escuela Superior de Física y Matemáticas, IPN S/N, Edificio 9 de la Unidad Profesional "Adolfo López Mateos", Col. Lindavista, Alc. Gustavo A. Madero, 07738, Mexico City, Mexico.
Context: "Nanostructure of graphene-reinforced with polymethyl methacrylate" (PMMA-G), and vice versa, is investigated using its molecular structure, in the present work. The PMMA-G nanostructure was constructed by bonding PMMA with graphene nanosheet in a sense to get three different configurations. Each configuration consisted of polymeric structures with three degrees of polymerization (such as monomers, dimers, and trimers polymers, respectively).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!