The test performance of a wideband acoustic transfer function (ATF) test and 226-Hz tympanometry was assessed in predicting the presence of conductive hearing loss, based on an air-bone gap of 20 dB or more. Two ATF tests were designed using an improved calibration method over a frequency range (0.25-8 kHz): an ambient-pressure test and a tympanometric test using an excess static pressure in the ear canal. Wideband responses were objectively classified using moment analyses of energy transmittance, which was a more appropriate test variable than energy reflectance. Subjects included adults and children of age 10 years and up, with 42 normal-functioning ears and 18 ears with a conductive hearing loss. Predictors were based on the magnitudes of the moment deviations from the 10th to 90th percentiles of the normal group. Comparing tests at a fixed specificity of 0.90, the sensitivities were 0.28 for peak-compensated static acoustic admittance at 226 Hz, 0.72 for ambient-pressure ATF, and 0.94 for pressurized ATF. Pressurized ATF was accurate at predicting conductive hearing loss with an area under the receiver operating characteristic curve of 0.95. Ambient-pressure ATF may have sufficient accuracy to use in some hearing-screening applications, whereas pressurized ATF has additional accuracy that may be appropriate for hearing-diagnostic applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.1625931 | DOI Listing |
Imaging Neurosci (Camb)
April 2024
Department of Electrical Engineering, Columbia University, New York, NY, United States.
Listeners with hearing loss have trouble following a conversation in multitalker environments. While modern hearing aids can generally amplify speech, these devices are unable to tune into a target speaker without first knowing to which speaker a user aims to attend. Brain-controlled hearing aids have been proposed using auditory attention decoding (AAD) methods, but current methods use the same model to compare the speech stimulus and neural response, regardless of the dynamic overlap between talkers which is known to influence neural encoding.
View Article and Find Full Text PDFFront Neurosci
January 2025
Neurology Associate P.C., Lincoln, NE, United States.
Introduction: As a hallmark feature of amyotrophic lateral sclerosis (ALS), bulbar involvement significantly impacts psychosocial, emotional, and physical health. A validated objective marker is however lacking to characterize and phenotype bulbar involvement, positing a major barrier to early detection, progress monitoring, and tailored care. This study aimed to bridge this gap by constructing a multiplex functional mandibular muscle network to provide a novel objective measurement tool of bulbar involvement.
View Article and Find Full Text PDFTrends Hear
January 2025
Key Laboratory of Noise and Vibration Research, Institute of Acoustics, Chinese Academy of Sciences, Beijing, China.
Wide dynamic range compression (WDRC) and noise reduction both play important roles in hearing aids. WDRC provides level-dependent amplification so that the level of sound produced by the hearing aid falls between the hearing threshold and the highest comfortable level of the listener, while noise reduction reduces ambient noise with the goal of improving intelligibility and listening comfort and reducing effort. In most current hearing aids, noise reduction and WDRC are implemented sequentially, but this may lead to distortion of the amplitude modulation patterns of both the speech and the noise.
View Article and Find Full Text PDFOtolaryngol Head Neck Surg
January 2025
Department of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan, USA.
Objective: Evaluate inpatient audiometry on clinical decision-making. Assess stakeholder perspectives on the practice of inpatient audiometry and financial impact.
Study Design: This is a mixed methods study utilizing retrospective chart review, a focus group, and financial analyses.
BMC Geriatr
January 2025
School of Medicine, Qom University of Medical Sciences, Qom, Iran.
Introduction: Intrinsic Capacity in integrated geriatric care emphasizes the importance of a thorough functional assessment. Monitoring the intrinsic capacity of older individuals provides standardized and reliable information to prevent early disability. This study assessed the relationship between intrinsic capacity and functional ability in older adults.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!