A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of coronary flow velocity reserve in the posterior descending coronary artery by contrast-enhanced transthoracic Doppler echocardiography. | LitMetric

Background: Although the measurement of coronary flow velocity (CFV) reserve (CFVR) in the left anterior descending coronary artery (LAD) by transthoracic Doppler echocardiography has been established, its success rate in the posterior descending coronary artery (PD) is still limited.

Objective: This study reports the feasibility and diagnostic accuracy of measuring CFVR in the PD by transthoracic Doppler echocardiography.

Methods: CFVR in both the distal LAD and the PD was measured in 151 consecutive patients before coronary angiography. PD flow was investigated under the guidance of a nondirectional Doppler color flow map with harmonic imaging in the modified apical 2-chamber view. Intravenous contrast agent, Levovist, was injected to enhance the CFV envelope at baseline and during hyperemia.

Results: CFVR was obtained in 145 patients in the LAD and 126 patients in the PD (P <.001). The success rate of CFVR measurement in the PD was significantly higher in the last 50 patients (88%) than it was in the first 50 patients (72%) (P <.05). CFVR in the PD was significantly lower for patients with significant stenosis of the artery supplying the PD than it was in those without stenosis (1.58 +/- 0.59 vs 2.45 +/- 0.72, P <.001). CFVR in the distal LAD was 1.40 +/- 0.62 in patients with significant LAD stenosis and 2.45 +/- 0.80 in those without stenosis (P <.001). If a cut-off value of CFVR < 2 was used, sensitivity, specificity, and accuracy for the diagnosis of significant (>50%) stenosis of the artery supplying the PD were 84%, 83%, and 83%, respectively, whereas for the LAD they were 91%, 75%, and 80%, respectively.

Conclusions: Noninvasive measurement of CFVR in the PD could be obtained in the majority of unselected patients using a nondirectional Doppler color flow map and contrast-enhanced harmonic imaging. The diagnostic accuracy of CFVR in the PD is similar to that of the LAD and, hence, has a potential clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2003.09.001DOI Listing

Publication Analysis

Top Keywords

descending coronary
12
coronary artery
12
transthoracic doppler
12
measurement coronary
8
coronary flow
8
flow velocity
8
posterior descending
8
doppler echocardiography
8
coronary
5
flow
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!