Alveolar gas exchange in patients with type 2 diabetes mellitus.

Endocr J

Department of Endocrinology, Faculty of Medicine, Baskent University, Ankara, Turkey.

Published: December 2003

The present study has been conducted to quantify and compare the capacity of gas exchange in patients with type 2 diabetes mellitus (DM) and healthy controls and also to investigate the effects of various factors on alveolar capillary permeability. A total of 37 subjects, 25 patients with DM and 12 healthy controls were recruited for the study. All the participants were evaluated with simple spirometric tests and simple breath carbonmonoxide (CO) diffusion test (DLCO). The ratio of DLCO value to the alveolar ventilation (VA) was used to assess alveolar membrane permeability. Diabetic patients were also evaluated in detail with respect to degenerative diabetic complications including the presence of microalbuminuria, advanced nephropathy, sensorial and autonomic neuropathy, retinopathy, hypertension and macrovascular disease. The results of simple spirometric tests which determined lung capacity were similar in the diabetic patients and the healthy controls. Ratio of DLCO/VA, which determines alveolar membrane permeability, revealed statistically significant decline in pulmonary gas exchange in the diabetic group (p: 0.037). Pearson correlation analysis revealed statistically significant correlation between duration of diabetes mellitus, age and urinary albumin excretion with DLCO/VA values (Pearson: -0.726, p: 0.001; Pearson: -0.438, p: 0.036; Pearson: -0.472, p: 0.023 respectively). This study demonstrated the decreased alveolar gas exchange capacity in diabetic patients compared with healthy controls. Detrimental effects of DM on alveolar capillaries were found to be correlated with age, duration of DM and urinary albumin excretion. Microalbuminuria was the only significant predictor of DLCO/VA.

Download full-text PDF

Source
http://dx.doi.org/10.1507/endocrj.50.663DOI Listing

Publication Analysis

Top Keywords

gas exchange
16
healthy controls
16
diabetes mellitus
12
diabetic patients
12
alveolar gas
8
exchange patients
8
patients type
8
type diabetes
8
patients healthy
8
simple spirometric
8

Similar Publications

High-incline walking is a relatively new trend with little comparative information. This study compared physiological and psychological differences between high-incline walking at 20% grade (HIW) and level-grade jogging (LGJ) at isocaloric intensities in young adults. Twenty-two participants (M = 11, F = 11) aged 19-31 years completed the study.

View Article and Find Full Text PDF

On October 11, 2018, in the Ulytau region of the Republic of Kazakhstan, the Soyuz-FG launch vehicle carrying a crewed MS-10 spacecraft failed. It resulted in the release into the fragile arid ecosystems of rocket propellants, i.e.

View Article and Find Full Text PDF

The present study was designed to highlight the ameliorative role of iron nanoparticles (FeNPs) against drought stress in spinach (Spinacia oleracea L.) plants. A pot experiment was performed in two-way completely randomize design with three replicates.

View Article and Find Full Text PDF

Objectives: A conservative oxygenation strategy is recommended in adult and pediatric guidelines for the management of acute respiratory distress syndrome to reduce iatrogenic lung damage. In the recently reported Oxy-PICU trial, targeting peripheral oxygen saturations (Spo2) between 88% and 92% was associated with a shorter duration of organ support and greater survival, compared with Spo2 greater than 94%, in mechanically ventilated children following unplanned admission to PICU. We investigated whether this benefit was greater in those who had severely impaired oxygenation at randomization.

View Article and Find Full Text PDF

Permeance-selectivity trade-offs are inherent to polymeric membranes. In fuel cells, thinner proton exchange membranes (PEMs) could enable higher proton conductance and increased power density with lower area-specific resistance (ASR), smaller ohmic losses, and lower ionomer cost. However, reducing thickness is accompanied by an increase in undesired species crossover harming performance and long-term efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!