A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reconstruction of orbital floor fracture using solvent-preserved bone graft. | LitMetric

Reconstruction of orbital floor fracture using solvent-preserved bone graft.

Plast Reconstr Surg

Plastic, Reconstructive, and Aesthetic Surgery Department, Gazi University Faculty of Medicine, Ankara, Turkey.

Published: January 2004

AI Article Synopsis

  • The orbital floor is commonly injured in facial trauma, requiring careful reconstruction to avoid poor aesthetic and functional outcomes.
  • Treatment involves using materials that support the orbital structure and maintain its volume, yet there’s no widely accepted method for the best reconstruction approach.
  • This study assessed the use of solvent-preserved cadaveric cranial bone grafts in 25 orbital floor fractures and found that postoperative complications were minimal, with no significant issues related to eye movement or graft resorption.

Article Abstract

The orbital floor is one of the most frequently damaged parts of the maxillofacial skeleton during facial trauma. Unfavorable aesthetic and functional outcomes are frequent when it is treated inadequately. The treatment consists of spanning the floor defect with a material that can provide structural support and restore the orbital volume. This material should also be biocompatible with the surrounding tissues and easily reshaped to fit the orbital floor. Although various autografts or synthetic materials have been used, there is still no consensus on the ideal reconstruction method of orbital floor defects. This study evaluated the applicability of solvent-preserved cadaveric cranial bone graft and its preliminary results in the reconstruction of the orbital floor fractures. Twenty-five orbital floor fractures of 21 patients who underwent surgical repair with cadaveric bone graft during a 2-year period were included in this study. Pure blowout fractures were determined in nine patients, whereas 12 patients had other accompanying maxillofacial fractures. Of the 21 patients, 14 had clinically evident diplopia (66.7 percent), 12 of them had enophthalmos (57.1 percent), and two of them had gaze restriction preoperatively. Reconstruction of the floor of the orbit was performed following either the subciliary or the transconjunctival approach. A cranial allograft was placed over the defect after sufficient exposure. The mean follow-up period was 9 months. Postoperative diplopia, enophthalmos, eye motility, cosmetic appearance, and complications were documented. None of the patients had any evidence of diplopia, limited eye movement, inflammatory reactions in soft tissues, infection, or graft extrusion in the postoperative period. Providing sufficient orbital volume, no graft resorption was detected in computed tomography scan controls. None of the implants required removal for any reason. Enophthalmos was seen in one patient, and temporary scleral show lasting up to 3 to 6 weeks was detected in another three patients. Satisfactory cosmetic results were obtained in all patients. This study showed that solvent-preserved bone, which is a nonsynthetic, human-originated, processed bioimplant, can be safely used in orbital floor repair and can be considered as another reliable treatment alternative.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.PRS.0000096704.34065.03DOI Listing

Publication Analysis

Top Keywords

orbital floor
28
bone graft
12
floor
9
reconstruction orbital
8
solvent-preserved bone
8
orbital
8
orbital volume
8
floor fractures
8
fractures patients
8
patients
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!