Purpose: High-precision external beam radiotherapy (EBRT) has been suggested as a potential alternative to endovascular brachytherapy for the treatment of coronary artery in-stent restenosis. The purpose of our study was to investigate and compare different options to define a smallest feasible target volume.

Methods And Materials: The cardiac motion of 17 coronary artery stents in 17 patients was studied by use of biplane conventional angiography, recorded during breath-hold. Each stent was reconstructed in three dimensions by use of biplane sets of frames covering an entire cardiac cycle. The volume traversed by the stent during the entire or part of the cardiac cycle was determined. Four options to define the stent-traversed volume (STV) as a target for high-precision EBRT were investigated.

Results: The mean STV during the entire cardiac cycle was 3.5 cm3; the STV represented less than 1% of the heart volume in all patients. The STV during the diastolic and systolic phase resulted in a mean reduction of 26.6% and 29.1%, respectively, compared with the STV during the entire cardiac cycle. The smallest STV, measured during a 160-ms interval within the cardiac cycle, resulted in a mean maximal reduction of 75.9% compared with the STV during the entire cardiac cycle.

Conclusions: The STV during the entire cardiac cycle represents a small potential target volume for high-precision EBRT. A significant reduction of this target volume is possible in case of definition during a selected interval within the cardiac cycle.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2003.08.017DOI Listing

Publication Analysis

Top Keywords

cardiac cycle
28
entire cardiac
24
coronary artery
16
stv entire
16
target volume
12
cardiac
10
cardiac motion
8
motion coronary
8
artery stents
8
volume high-precision
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!