A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hemolysis in an electromechanical driven pulsatile total artificial heart. | LitMetric

Hemolysis in an electromechanical driven pulsatile total artificial heart.

Artif Organs

Department of Cardiovascular Surgery, Chiba, Japan.

Published: December 2003

A motor rotation in an electromechanically-driven pulsatile total artificial heart (TAH) may influence hemolysis. This study is designed to evaluate motor rotational conditions of the TAH and choose a suitable condition to obtain the least hemolytic characteristics. The TAH was driven in two motor rotational conditions: a constant motor rotational speed (rpm) mode (mode A) and a gradually increasing rpm mode (mode B). In these two modes, a maximum dP/dt value and a degree of hemolysis were measured and compared. The TAH was connected to an in vitro testing loop. In each mode, the TAH was driven with a fixed pumping rate of 100 bpm. A preload and an afterload were held at 15 and 100 mm Hg, respectively. The outflow of the TAH was maintained at 4.0 L/min. The maximum dP/dt in mode A and mode B was 5914 +/- 405 mm Hg/s and 2953 +/- 191 mm Hg/s, respectively. The NIH value obtained from mode A and mode B was 0.063 +/- 0.005 g/100 L and 0.026 +/- 0.003 g/100 L, respectively. The results demonstrated that the TAH driven in a gradually increasing rpm mode reduces both a maximum dP/dt value and a degree of hemolysis. The gradually increasing rpm mode is a suitable driving condition to obtain the least hemolytic characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2003.07088.xDOI Listing

Publication Analysis

Top Keywords

rpm mode
16
mode mode
16
motor rotational
12
tah driven
12
gradually increasing
12
increasing rpm
12
maximum dp/dt
12
mode
11
pulsatile total
8
total artificial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!