Objective: The purpose of this study was to evaluate the complication rates associated with indwelling venous access devices in patients with gynecologic malignancies.
Methods: Following IRB approval, a computerized database identified women that had indwelling access devices placed for chemotherapy from March 1999 to June 2001. A retrospective chart review identified 116 venous access devices that were placed in 104 patients. All devices were silicone and had a closed tip design with a three-position valve. Data were collected on patient demographics, clinicopathologic features, type of venous device, and complications. The chi(2) test was used for statistical analysis.
Results: Of the 104 patients, 79 had ovarian cancer, 11 had uterine cancer, 10 had cervical cancer, 2 had fallopian tube cancer, and 2 had vaginal cancer. The median age was 61 years. There were a total of 116 venous devices placed: 65 external catheters (EC) and 51 subcutaneous ports (SP). Seventy-nine percent of the patients were administered low-dose coumadin (1 mg/day) for catheter clot prophylaxis. There were three operative complications in the EC group and two in the SP group (P = NS). The most common postoperative complications were infection and thrombosis. Nineteen patients in the EC group experienced a catheter-related infection versus 5 in the SP group (P = 0.025). In the EC group, there were 11 cases of site infection and 8 cases of line sepsis. In contrast, there were 3 cases of exit site infection and 2 cases of line sepsis in the SP group. Deep vein thrombosis occurred in 5 patients with EC and 3 patients with SP (P = NS). Twenty-seven patients with EC had the device removed for catheter-related complications versus 2 patients with SP (P = 0.001). Six patients inadvertently removed their EC.
Conclusion: There is a significantly higher postoperative complication rate in gynecologic oncology patients with external catheters versus subcutaneous ports. Infection and catheter-related malfunction are more common in patients with external catheters. We recommend the use of subcutaneous ports in the majority of patients with gynecologic malignancies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ygyno.2003.08.015 | DOI Listing |
Sci Data
January 2025
School of Medicine, Anhui University of Science and Technology, Huainan, 232001, China.
Ultrasound is a primary diagnostic tool commonly used to evaluate internal body structures, including organs, blood vessels, the musculoskeletal system, and fetal development. Due to challenges such as operator dependence, noise, limited field of view, difficulty in imaging through bone and air, and variability across different systems, diagnosing abnormalities in ultrasound images is particularly challenging for less experienced clinicians. The development of artificial intelligence (AI) technology could assist in the diagnosis of ultrasound images.
View Article and Find Full Text PDFNat Commun
January 2025
Beijing Advanced Innovation Center for Integrated Circuits, School of Integrated Circuits, Peking University, Beijing, China.
Compute-in-memory based on resistive random-access memory has emerged as a promising technology for accelerating neural networks on edge devices. It can reduce frequent data transfers and improve energy efficiency. However, the nonvolatile nature of resistive memory raises concerns that stored weights can be easily extracted during computation.
View Article and Find Full Text PDFJ Surg Res
January 2025
Division of Surgical Oncology, Department of Surgery, University of Nebraska Medical Center, Omaha, Nebraska. Electronic address:
Introduction: Gender disparities exist in nonresearch industry payments to U.S. physicians, but detailed analyses specific to surgeons are limited.
View Article and Find Full Text PDFInt J Surg Case Rep
January 2025
Department of Surgery, College of Medicine and Health Sciences, Comprehensive Specialized Hospital, University of Gondar, Gondar, Ethiopia.
Introduction And Importance: Myiasis is an overlooked public health issue, with urogenital myiasis (UGM) being particularly rare, as evidenced by only 59 reported cases worldwide from 1975 to 2017. There is a notable scarcity of cases involving patients with prolonged catheter use related to SCI. The interaction of SCI with the complications associated with indwelling urinary devices is less frequently discussed in prior literature.
View Article and Find Full Text PDFBr J Nurs
January 2025
Postgraduate Program in Nursing, Nursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina, Florianopolis, Brazil.
Highlights: PIVCs often cause pain, irritation, or infection. Regular and careful catheter checks can decrease complications and improve patient outcomes. Implementation of the I-DECIDED® tool led to fewer idle catheters and complications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!