A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A prospective evaluation of interrupted nitinol surgical clips in arteriovenous fistula for hemodialysis. | LitMetric

A prospective evaluation of interrupted nitinol surgical clips in arteriovenous fistula for hemodialysis.

Am J Surg

Division of Vascular Surgery and Endovascular Therapy, Michael E. DeBakey Department of Surgery, Baylor College of Medicine and the Methodist Hospital, Houston VAMC (112), Houston, TX 77030, USA.

Published: December 2003

Background: The use of a self-closing nitinol surgical clip (Coalescent Surgical U-Clip) is a novel technique of creating an interrupted vascular anastomosis, which also eliminates the knot tying associated with a conventional vascular anastomosis. The purpose of this study was to compare the clinical outcome of arteriovenous fistulae (AVF) for hemodialysis as constructed using interrupted U-Clip devices and conventional continuous polypropylene sutures.

Methods: We prospectively studied the clinical course of 132 patients (149 access) undergoing either forearm autologous arteriovenous fistula (FAVF, n = 69) or upper arm autologous arteriovenous fistula (UAVF, n = 80) or creations during a 39-month period. Among the FAVF, U-Clips and polypropylene sutures were used in 37 and 32 anastomoses, respectively. Among the UAVF, U-Clips and polypropylene sutures were used in 41 and 30 anastomoses, respectively. Primary patency, complication, and maturation rates were analyzed.

Results: Clipped FAVF had an improved maturation rate at 6 weeks (32 of 37, 86%) when compared with sutured FAVF (22 of 32, 69%, P <0.05). There was no difference in the maturation rate among UAVF constructed with either U-Clips or sutures (88% versus 87%, not significant). The primary patency rates at 12, 24, and 36 months were 91%, 84%, and 75% for the clipped FAVF; and 83%, 74%, and 61% for the sutured FAVF (P <0.05) There was no difference in the patency rate of UAVF constructed with either U-Clips or polypropylene sutures at either 12, 24 or 36 moths (91%, 80%, and 75% versus 83%, 77%, and 69%, respectively).

Conclusions: The U-Clips are a viable alternative to sutures for creating vascular anastomosis. It provides a improved maturation and patency rates when compared with the conventional sutured AVF in the forearm. The clinical benefit of the U-Clips may be due in part to the improved compliance created by the interrupted anastomotic technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2003.08.007DOI Listing

Publication Analysis

Top Keywords

arteriovenous fistula
12
nitinol surgical
8
vascular anastomosis
8
autologous arteriovenous
8
u-clips polypropylene
8
polypropylene sutures
8
sutures anastomoses
8
prospective evaluation
4
evaluation interrupted
4
interrupted nitinol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!