A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid and sensitive static headspace gas chromatography-mass spectrometry method for the analysis of ethanol and abused inhalants in blood. | LitMetric

Rapid and sensitive static headspace gas chromatography-mass spectrometry method for the analysis of ethanol and abused inhalants in blood.

J Chromatogr B Analyt Technol Biomed Life Sci

Camelracing Laboratory, Forensic Science Laboratory, P.O. Box 253, Abu Dhabi, United Arab Emirates.

Published: January 2004

A sensitive and specific method using static headspace gas chromatography coupled with mass spectrometry (GC/MS) has been developed for the quantitative determination of ethanol in biological fluids using n-propanol as internal standard. Gas chromatography was performed in isothermal mode with a GC run time of 2.6 min. The quantification was performed using scan mode abstracting a quantitative ion and a qualifier ion for ethanol and for the internal standard. The method was linear (r(2), 0.999, in the concentration range of 5-200 mg/dl), specific (no interference from methanol acetaldehyde, acetone or from endogenous materials), sensitive (limit of quantification and limit of detection of 0.2 and 0.02 mg/dl, respectively) and robust (less than 5% inter- and intra-assay coefficient of variation). A slightly modified method was also developed for the quantification of five commonly abused inhalants (dichloromethane, ethyl acetate, benzene, toluene and xylene) in blood. The method used a gradient GC program with a run time of 8 min. The quantification was performed using scan mode and integrating the area under the peak using trichloroethane as an internal standard. Without optimization, the method was linear (from 5 to 100 mg/l) and sensitive.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2003.11.003DOI Listing

Publication Analysis

Top Keywords

internal standard
12
static headspace
8
headspace gas
8
abused inhalants
8
gas chromatography
8
time min
8
min quantification
8
quantification performed
8
performed scan
8
scan mode
8