Bisphenol A (BPA) and alkylphenols (APs) are widely used industrial chemicals. BPA is used to manufacture polycarbonate plastic and epoxy resins; APs are used to make alkylphenol ethoxylates, common nonionic surfactants. BPA and APs can leach into the environment during industrial production and after degradation of the polycarbonate plastics and nonionic surfactants. Environmental exposure to these phenolic compounds has been associated with adverse reproductive and developmental effects in wildlife. We developed a sensitive and robust method for measuring BPA and six APs; 3-tert-butylphenol, 4-tert-butylphenol, 4-n-octylphenol, 4-tert-octylphenol, 4-n-nonylphenol, and technical-grade nonylphenol in urine. The method is based on the use of automated solid-phase extraction (SPE) coupled to isotope dilution-gas chromatography/mass spectrometry (GC/MS). During the automated SPE process, the phenols are both extracted from the urine matrix and derivatized, using pentafluorobenzyl bromide, on commercially available styrene-divinylbenzene copolymer-based SPE cartridges. After elution from the SPE column, the derivatized phenols in the SPE eluate are analyzed by GC/MS. The method, validated on spiked pooled urine samples and on urine samples from exposed persons, has limits of detection of approximately 0.1 ng in 1 mL of urine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac0303158 | DOI Listing |
Asian J Transfus Sci
November 2023
Department of Transfusion Medicine, Apollo Multispeciality Hospitals, Kolkata, West Bengal, India.
Background: Examples of group B red cells that react weakly or not at all with anti-B have been described. Subgroups of B such as B, B, B, and B are rare and are less frequently reported. We studied the frequency of subgroups of B in our healthy blood donor population and serologically characterized and differentiated these subgroups.
View Article and Find Full Text PDFAsian J Transfus Sci
October 2024
Department of Transfusion Medicine, Sri Balaji Action Medical Institute, New Delhi, India.
Background: High titers of anti-A and anti-B are considered to be one reason for hemolytic transfusion reactions and ABO hemolytic disease in fetus and neonates. There is no consensus for critical ABO antibody titers to guide transfusion or transplant decisions. Implementation of ABO titer measurement can favor reduction in transfusion reactions in nongroup "O" recipients.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Department of Physics, Novosibirsk State University, 2 Pirogov Str., Novosibirsk 630090, Russia.
Nowadays, nucleic acid derivatives capable of modulating gene expression at the RNA level have gained widespread recognition as promising therapeutic agents. A suitable degree of biological stability of oligonucleotide therapeutics is required for in vivo application; this can be most expeditiously achieved by the chemical modification of the internucleotidic phosphate group, which may also affect their cellular uptake, tissue distribution and pharmacokinetics. Our group has previously developed a strategy for the chemical modification of the phosphate group via the Staudinger reaction on a solid phase of the intermediate dinucleoside phosphite triester and a range of, preferably, electron deficient organic azides such as sulfonyl azides during automated solid-phase DNA synthesis according to the conventional β-cyanoethyl phosphoramidite scheme.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan, ROC. Electronic address:
Background: To integrate valves, manifolds, and solid-phase extraction (SPE) columns into a compact device is technically difficult. Four-dimensional printing (4DP) technologies, employing stimuli-responsive materials in three-dimensional printing (3DP), are revolutionizing the fabrication, functionality, and applicability of stimuli-responsive analytical devices that can show time-dependent shape programming to enable more complex geometric designs and functions. However, 4D-printed stimuli-responsive actuators and valves utilized to control flowing streams in SPE applications remain rare.
View Article and Find Full Text PDFClin Chem Lab Med
January 2025
Laboratory of Clinical Pathology, Azienda Sanitaria Universitaria Integrata, Udine, Italy.
Objectives: External quality assessment (EQA) programs play a pivotal role in harmonizing laboratory practices, offering users a benchmark system to evaluate their own performance and identify areas requiring improvement. The objective of this study was to go through and analyze the UK NEQAS "Immunology, Immunochemistry and Allergy" EQA reports between 2012 and 2021 to assess the overall level of harmonization in autoimmune diagnostics and identify areas requiring improvement for future actions.
Methods: The EQA programs reviewed included anti-nuclear (ANA), anti-dsDNA, anti-centromere, anti-extractable nuclear antigen (ENA), anti-phospholipids, anti-neutrophil cytoplasm (ANCA), anti-proteinase 3 (PR3), anti-myeloperoxidase (MPO), anti-glomerular basement membrane (GBM), rheumatoid factor (RF), anti-citrullinated protein antibodies (ACPA), mitochondrial (AMA), liver-kidney-microsomal (LKM), smooth muscle (ASMA), APCA, and celiac disease antibodies.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!