Capillary electrophoresis (CE) was coupled to ICPMS in order to combine the good performance of this separation technique with the high sensitivity of the ICPMS for the analysis of plutonium and neptunium oxidation states. The combination of a fused-silica capillary with a MicroMist AR 30-I-FM02 nebulizer and a Cinnabar small-volume cyclonic spray chamber yielded the best separation results. With this setup, it was possible to separate a model element mixture containing neptunium (NpO2(+)), uranium (UO2(2+)), lanthanum (La3+), and thorium (Th4+) in 1 M acetic acid. The same conditions were also suitable for the separation of various oxidation states of plutonium and neptunium in different aqueous samples. All separations were obtained within less than 15 min. A detection limit of 50 ppb identical with 2 x 10(-7) M (3-fold standard deviation of a blank) was achieved. To prove the negligible disturbance of the plutonium and neptunium redox equilibria during the CE separations, plutonium and neptunium speciation by CE-ICPMS in acidic solutions was compared with the results of UV/visible absorption spectroscopy and was found to be in good agreement. The CE-ICPMS system was also applied to study the reduction of Pu(VI) in a humic acid-containing groundwater at different pH values.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac0347213 | DOI Listing |
Talanta
January 2025
National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Chiba, Chiba, 263-8555, Japan; Department of Physics, Faculty of Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba, 274-8510, Japan.
Natural uranium isotopes have extremely long half-lives; therefore, analytical methods based on the number of atoms, such as X-ray fluorescence (XRF) analysis, are suitable for uranium detection. However, XRF measurements cannot be used to detect the major isotopes of americium when present in amounts barely detectable using radiation measurements, owing to their relatively short half-lives. Because of α-decay-induced internal conversion, where orbital electrons are emitted instead of γ-rays, these nuclides emit characteristic X-rays.
View Article and Find Full Text PDFEnviron Pollut
November 2024
The Key Laboratory of Coastal and Island Development of Ministry of Education, School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing, 210023, China.
ACS Environ Au
November 2024
Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550, United States.
Actinides are elements that are often feared because of their radioactive nature and potentially devastating consequences to humans and the environment if not managed properly. As such, their chemical interactions with the biosphere and geochemical environment, i.e.
View Article and Find Full Text PDFMicrosc Microanal
November 2024
Radioisotope Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830, USA.
The production of plutonium-238 through irradiation of neptunium-237 (237Np) target materials for the use in radioisotope thermoelectric generators is paramount for continued deep space exploration. This work employs scanning electron microscopy to analyze 237Np materials coupled with a well-developed image analysis framework (Morphological Analysis for Material Attribution, or MAMA) to determine the degree of micron-scale homogeneity in the materials. This work demonstrated how the quantification of particle characteristics can validate production materials and affirm the qualitative similarities observed in micrographs.
View Article and Find Full Text PDFInorg Chem
September 2024
Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!