KISS for STRAP: user extensions for a protein alignment editor.

Bioinformatics

Institut für Biochemie, Charité, Monbijoustr. 2, Berlin 10117, Germany.

Published: December 2003

Summary: The Structural Alignment Program STRAP is a comfortable comprehensive editor and analyzing tool for protein alignments. A wide range of functions related to protein sequences and protein structures are accessible with an intuitive graphical interface. Recent features include mapping of mutations and polymorphisms onto structures and production of high quality figures for publication. Here we address the general problem of multi-purpose program packages to keep up with the rapid development of bioinformatical methods and the demand for specific program functions. STRAP was remade implementing a novel design which aims at Keeping Interfaces in STRAP Simple (KISS). KISS renders STRAP extendable to bio-scientists as well as to bio-informaticians. Scientists with basic computer skills are capable of implementing statistical methods or embedding existing bioinformatical tools in STRAP themselves. For bio-informaticians STRAP may serve as an environment for rapid prototyping and testing of complex algorithms such as automatic alignment algorithms or phylogenetic methods. Further, STRAP can be applied as an interactive web applet to present data related to a particular protein family and as a teaching tool.

Requirements: JAVA-1.4 or higher.

Availability: http://www.charite.de/bioinf/strap/

Download full-text PDF

Source
http://dx.doi.org/10.1093/bioinformatics/btg354DOI Listing

Publication Analysis

Top Keywords

strap
7
protein
5
kiss strap
4
strap user
4
user extensions
4
extensions protein
4
protein alignment
4
alignment editor
4
editor summary
4
summary structural
4

Similar Publications

Background: The Apple Watch provides promising health data that could aid in increasing exercise adherence; regular exercise can help individuals manage and prevent diseases such as obesity and cardiovascular disease. However, the impact of skin pigmentation on the accuracy of the Apple Watch Series 9 for measures of energy expenditure (EE) and heart rate (HR) is unknown.

Purpose: The purpose of this study was to determine the accuracy of the Apple Watch Series 9 on various skin pigmentations for measures of EE and HR.

View Article and Find Full Text PDF

Perceptions Among Mental Health Professionals Regarding the Intrusiveness of Coercive Measures: A Danish Regional Survey.

J Forensic Nurs

December 2024

Author Affiliations:Forensic Mental Health Research Unit, Middelfart, Faculty of Health Science, Department of Regional Health Research, University of Southern Denmark.

Background: Although hotly disputed, coercive measures are widely used in mental health services globally. In Denmark, to ensure the rights of patients, special psychiatric legislation that emphasizes the imperative to always use the least intrusive intervention has been implemented. This raises the question of which coercive measures are perceived as being less intrusive than others.

View Article and Find Full Text PDF

Background: The development of wearable solutions for tracking upper limb motion has gained research interest over the past decade. This paper provides a systematic review of related research on the type, feasibility, signal processing techniques, and feedback of wearable systems for tracking upper limb motion, mostly in rehabilitation applications, to understand and monitor human movement.

Objective: The aim of this article is to investigate how wearables are used to capture upper limb functions, especially related to clinical and rehabilitation applications.

View Article and Find Full Text PDF

Introduction: Military pilots are subjected to unique pulmonary demands, particularly in high performance jets. The hypobaric environment necessitates use of on-board oxygen, breathing masks, and regulators to increase oxygen pressure, affecting ventilation and breathing responses. Safety features like pilot flight equipment and strapping into an ejection seat further impact pilot pulmonary function.

View Article and Find Full Text PDF

Morphogenesis and functional aspects of the muscular layer of the middle deep cervical fascia in humans.

Tissue Cell

December 2024

Department of Anatomy and Embryology, Faculty of Medicine, Universidad Complutense de Madrid (UCM), Madrid, Spain; UCM Research Group No. 920202, Faculty of Medicine, Universidad Complutense de Madrid (UCM), Madrid, Spain.

Background: In recent years, the fasciae of the human body have received significant attention because of their crucial role in the transmission of muscle force. However, studies on the development of the fasciae, particularly the cervical fascia, remain scarce.

Purpose: This study was performed to examine the development of the fascia of the infrahyoid strap muscles, also known as the middle layer of the deep cervical fascia (MDCF), in 17 human embryos aged 6-8 weeks and 20 human foetuses aged 9-14 weeks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!