Objective: This study investigated the effects on global cardiac function and myocardial energetics of limiting progressive dilatation after infarction by means of a woven polyester jacket cardiac support device. We hypothesized that placement of the cardiac support device results in a decrease in myocardial wall stress and improvement in cardiac function and myocardial energetics.

Methods: To investigate the effect of passive constraint on left ventricular function and mechanics, a total of 10 sheep were studied with pressure-volume analysis and magnetic resonance imaging. A baseline study was followed by the creation of an anterior infarct. After 1 week, the animals underwent a second study. The cardiac support device was then placed over the epicardium in 5 sheep; the remaining animals served as controls. A terminal study was performed at 2 months after the infarct.

Results: The cardiac support device group at the terminal study exhibited a decrease in end-diastolic volume (control 110.3 +/- 19.8 mL vs cardiac support device 67.6 +/- 4.7 mL, P =.006) and an improved ejection fraction (control 15.5% +/- 5.7% vs cardiac support device 29.46% +/- 4.42%, P =.008) relative to the control group. Myocardial energetics were also enhanced in the cardiac support device group, as evidenced by the significant improvements in potential energy (control 2015 +/- 503 mL. mm Hg/beat vs cardiac support device 885 +/- 220 mL. mm Hg/beat, P =.006), efficiency (control 39.4% +/- 13.6% vs cardiac support device 59.8% +/- 8.5%, P =.044), and oxygen consumption (control 0.072 +/- 0.013 mL O(2)/beat vs cardiac support device 0.052 +/- 0.007 mL O(2)/beat, P =.034).

Conclusion: Passive constraint with the cardiac support device after infarct prevents further remodeling and may stimulate reverse remodeling in heart failure secondary to acute myocardial infarction. These results suggest that in human beings placement of the cardiac support device after a large anterior myocardial infarction may be effective in halting the remodeling process that often leads to end-stage heart failure. If proved effective, placement of a cardiac support device after large heart attacks has the potential to decrease the incidence of heart failure that results after large myocardial infarctions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-5223(03)00739-6DOI Listing

Publication Analysis

Top Keywords

cardiac support
52
support device
52
heart failure
16
cardiac
15
support
13
device
13
myocardial infarction
12
placement cardiac
12
+/-
10
left ventricular
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!