Purpose: Prospective studies in the general surgery literature have shown fewer wound related complications with closed suction drainage than with open passive drainage. Nevertheless, some urologists avoid closed suction drains after partial nephrectomy mainly because of a theoretical increased risk of a prolonged urinary leak or delayed hemorrhage.

Materials And Methods: We reviewed the records of 184 patients who underwent 197 consecutive partial nephrectomies at our institution. Closed suction or open passive (Penrose) drainage was used based on surgeon preference. Drain type was compared with duration of use and the incidence of relevant complications.

Results: A Penrose drain was used in 37.6% (74 of 197) of partial nephrectomies and a closed suction drain was used in 62.4% (123). Clinical characteristics were equivalent between both groups, including age, body mass index, tumor size (mean 3.1 cm), number of renal tumors excised, estimated blood loss and operative time. There was no statistically significant difference in the duration of drainage between the Penrose group (mean 7.1 days) and the closed suction group (7.8 days). While we found variation in the incidence of relevant complications by drain type, none of these differences was statistically significant. Complications included prolonged urinary drainage in 7.6% of cases (8.9% closed suction, 5.4% Penrose), wound infection or perinephric abscess in 3.6% (2.4% closed suction, 5.4% Penrose) and delayed hemorrhage in 1.5% (2.4% closed suction, 0 Penrose).

Conclusions: No statistically significant differences in postoperative morbidity were observed between the use of closed suction or Penrose retroperitoneal drains after partial nephrectomy.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ju.0000099940.02698.38DOI Listing

Publication Analysis

Top Keywords

closed suction
40
partial nephrectomy
12
closed
10
suction
9
suction penrose
8
penrose drainage
8
open passive
8
drains partial
8
prolonged urinary
8
partial nephrectomies
8

Similar Publications

Evaluation of postoperative drainage necessity in posterior atlantoaxial fixation via intermuscular approach for odontoid fracture.

Sci Rep

January 2025

Department of Orthopedics, Shanghai Changzheng Hospital, Naval Medical University, 415 Fengyang Road, Huangpu District, Shanghai, 200003, People's Republic of China.

The necessity of routinely placing closed suction wound drainage in spinal surgery has been questioned. This study aims to assess if closed suction wound drainage is necessary for posterior atlantoaxial fixation via intermuscular approach. The functional outcomes of these 40 patients who underwent posterior atlantoaxial fixation via intermuscular approach without drainage tube (Group A) were compared with that of a control group, which consisted of 68 randomly enrolled cases with posterior atlantoaxial fixation via intermuscular approach with drainage tube (Group B).

View Article and Find Full Text PDF

Control of Corner Separation in Compressor Cascade Using Biomimetic Fish Scales Structure.

Biomimetics (Basel)

December 2024

Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan.

In this study, a fish scale structure with low viscous drag was proposed and applied to the suction surface of a compressor cascade to reduce total pressure loss and suppress corner separation, a key source of compressor inefficiency. By using CFD simulations, the biomimetic structure was identified and integrated into the cascade design. To evaluate its effects, we analyzed secondary flow structures using 2D projected streamlines, axial velocity density (AVD), and vortex visualization techniques.

View Article and Find Full Text PDF

Deep sternal wound infection (DSWI) is a rare but potentially devastating complication of median sternotomy performed in cardiac surgery. This report summarizes the nursing management of two pediatric cases with a DSWI treated using Do It Yourself (DIY) negative pressure suction (DIY-NPS) after surgery. The technique maintains a continuous suction pressure of 75 mmHg and intermittently flushes small volumes of fluid to stimulate granulation tissue formation and control systemic infection.

View Article and Find Full Text PDF

Capillary-Enhanced Biomimetic Adhesion on Icy Surfaces for High-Performance Antislip Shoe-Soles.

ACS Appl Mater Interfaces

December 2024

Centre for MicroElectroMechanical Systems (CMEMS), University of Minho, Azurem Campus, 4800-058 Guimaraes, Portugal.

The World Health Organization (WHO) reports 684,000 deaths/year due to slips and falls (SFs), with ∼38 million people requiring medical attention per annum. In particular, SFs on ice surfaces account for 45% of all SF incidents, costing over $100 billion globally in healthcare, intensive care, and insurance expenses. Current antislip solutions focus on hydrophobicity to repel interfacial fluids, aiming to maintain solid-to-solid contact.

View Article and Find Full Text PDF

Vacuum-assisted delivery (VAD) uses a vacuum cup on the fetal scalp to apply traction during uterine contractions, assisting complicated vaginal deliveries. Despite its widespread use, VAD presents a higher risk of neonatal morbidity compared to natural vaginal delivery and biomechanical evidence for safe VAD traction forces is still limited. The aim of this study is to develop and assess the feasibility of an experimental VAD testing setup, and investigate the impact of traction forces on fetal brain deformation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!