A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Laser Doppler flowmetry in non-human primate stroke studies: model refinement for pre-clinical development of cerebroprotective strategies. | LitMetric

Background: Safety, feasibility, and efficacy trials in non-human primate stroke models are essential to the evaluation of experimental therapies and their translation to humans. Although Laser Doppler Flowmetry has been successfully employed in rodent stroke to continuously monitor cerebral blood flow, it has not been applied in primate studies. This investigation examined the utility of Laser Doppler Flowmetry in refining an existing baboon model of cerebral ischemia/reperfusion.

Method: Continuous Laser Doppler Flowmetry monitoring was used, in non-human primates, to document local cerebral blood flow before, during, and after middle cerebral artery territory occlusion. In each baboon (n = 7) a single Doppler probe was placed into the left frontal cortex through a precoronal burr hole. Correlations between Laser Doppler Flowmetry values and latencies to Motor Evoked Potential dropout were compared using a linear regression model.

Findings: Placement of the Laser Doppler probe was easily accomplished in all animals. Laser Doppler Flowmetry tracings accurately documented blood flow changes that occurred with each technical manipulation during the procedure. Laser Doppler confirmed decreased perfusion that coincided both regionally and temporally with vessel occlusion. Depth of ischemia as measured by Laser Doppler Flowmetry was associated with Motor Evoked Potential dropout latencies for individual animals.

Conclusions: Continuous, single probe Laser Doppler Flowmetry is a reliable method of documenting perfusion changes following middle cerebral artery territory occlusion in a baboon model of reperfused stroke. This advanced intraoperative monitoring technique may lead to more accurate evaluation of acute stroke therapies in pre-clinical trials.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00701-003-0136-9DOI Listing

Publication Analysis

Top Keywords

laser doppler
40
doppler flowmetry
32
blood flow
12
laser
10
doppler
10
flowmetry
8
non-human primate
8
primate stroke
8
cerebral blood
8
baboon model
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!