The sensitivity of contrast-enhanced harmonic gray scale imaging was compared with that of power Doppler sonography in depicting tumor vascularity and contrast enhancement of hepatocellular carcinoma (HCC) identified by angiography-assisted computed tomography (CT). One hundred thirty-nine classic HCC nodules (108 patients), each appearing as a high-attenuation mass on early-phase CT during hepatic arteriography and as a perfusion defect on CT during arterial portography, were evaluated. Vascular findings and contrast enhancement patterns were evaluated by contrast-enhanced harmonic gray scale imaging. Arterial pulsatile flow into each nodule was checked by power Doppler sonography. Sensitivity of each modality for depicting tumor vascularity was examined by angiography-assisted CT findings as the gold standard. The sensitivity of contrast-enhanced harmonic gray scale imaging (134/139, 96.4%) was significantly greater than that of power Doppler sonography (96/139, 69.1%) (P<0.05). Twenty-six of twenty-seven nodules (96.3%) in the lateral segment, in which motion artifact is likely, were enhanced by contrast-enhanced harmonic gray scale imaging. Contrast-enhanced harmonic gray scale imaging is more sensitive than power Doppler sonography and is a noninvasive method that can be used as effectively as angiography-assisted CT to evaluate tumor vessels and contrast enhancement of HCC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s1386-6346(03)00265-1 | DOI Listing |
Endoscopy
December 2024
Department of Gastroenterology and Hepatology, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan.
J Med Case Rep
October 2024
Division of Gastroenterology and Hepatology, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan.
Background: Cryptococcus is an opportunistic infection acquired through inhalation from the environment, primarily affecting individuals with compromised immune systems. It typically leads to pneumonia upon passing through lung tissue. The infection can disseminate to various organs via the bloodstream, resulting in meningitis or encephalitis in the central nervous system.
View Article and Find Full Text PDFPhys Med Biol
October 2024
Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, SHFJ, Orsay, France.
Cavitation dose monitoring plays a key role in ultrasound drug delivery to the brain. The use of capacitive micromachined ultrasonic transducer (CMUT) technology has a great potential for passive cavitation detection (PCD).Here, a circular (diameter 7 mm) CMUT centered at 5 MHz was designed to be inserted into a therapeutic transducer (1.
View Article and Find Full Text PDFEndoscopy
December 2024
Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!