Bridging nerve gaps by means of autologous nerve grafts involves donor nerve graft harvesting. Recent studies have focused on the use of alternative methods, and one of these is the use of biodegradable nerve guides. After serving their function, nerve guides should degrade to avoid a chronic foreign body reaction. The in vitro degradation, in vitro cytotoxicity, hemocompatibility, and short-term in vivo foreign body reaction of poly((65)/(35) ((85)/(15) (L)/(D)) lactide-epsilon-caprolactone) nerve guides was studied. The in vitro degradation characteristics of poly(DLLA-epsilon-CL) nerve guides were monitored at 2-week time intervals during a period of 22 weeks. Weight loss, degree of swelling of the tube wall, mechanical strength, thermal properties, and the intrinsic viscosity of the nerve guides were determined. Cytotoxicity was studied by measuring the cell proliferation inhibition index (CPII) on mouse fibroblasts in vitro. Cell growth was evaluated by cell counting, while morphology was assessed by light microscopy. Hemocompatibility was evaluated using a thrombin generation assay and a complement convertase assay. The foreign body reaction against poly(DLLA-epsilon-CL) nerve guides was investigated by examining toluidine blue stained sections. The in vitro degradation data showed that poly(DLLA-epsilon-CL) nerve guides do not swell, maintain their mechanical strength and flexibility for a period of about 8-10 weeks, and start to lose mass after about 10 weeks. Poly(DLLA-epsilon-CL) nerve guides were classified as noncytotoxic, as cytotoxicity tests demonstrated that cell morphology was not affected (CPII 0%). The thrombin generation assay and complement convertase assay indicated that the material is highly hemocompatible. The foreign body reaction against the biomaterial was mild with a light priming of the immunesystem. The results presented in this study demonstrate that poly((65)/(35) ((85)/(15) (L)/(D)) lactide-epsilon-caprolactone) nerve guides are biocompatible, and show good in vitro degradation characteristics, making these biodegradable nerve guides promising candidates for bridging peripheral nerve defects up to several centimeters.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.10157DOI Listing

Publication Analysis

Top Keywords

nerve guides
44
vitro degradation
20
foreign body
16
body reaction
16
polydlla-epsilon-cl nerve
16
nerve
15
guides
11
biodegradable nerve
8
poly65/35 85/15
8
85/15 l/d
8

Similar Publications

Objective: To evaluate the outcomes and efficacy of robot-assisted radical prostatectomy (RARP) using the Versius robotic surgical system, aiming to provide comprehensive data on perioperative outcomes, postoperative recovery, and complications.

Patient And Methods: All cases of RARP using the CMR Versius platform performed at Cairo University Hospital over a two-year period were enrolled in this study. All patients had pathologically confirmed prostate cancer in both localized and locally advanced stages.

View Article and Find Full Text PDF

Background: The objective was to investigate if cryoneurolysis were superior to sham in reducing pain intensity in patients with chronic knee osteoarthritis. We hypothesized that cryoneurolysis was an effective and safe therapy to reduce chronic pain in patients with knee osteoarthritis.

Methods: The study was a randomized, double-blind, sham-controlled.

View Article and Find Full Text PDF

Abolition of Aorticorenal Ganglia Pacing Responses Improves Denervation Efficacy.

Hypertension

January 2025

Cardiology Department (P.B., X.L., V.T.T., M.A.B., A.V., E.Y., D.M.N., U.P., J.L., S.P.T., P.C.Q.), Westmead Hospital, Sydney, Australia.

Background: Transcatheter renal denervation (RDN) remains inconsistent despite developments in ablation technologies, due to the lack of an intraprocedural physiological end point.

Objective: To identify whether aorticorenal ganglion (ARG) guided RDN using microwave (MW) catheter leads to more consistent denervation outcomes compared with empirical MW ablation.

Methods: Pigs underwent sham procedure (n=8) or bilateral RDN using an in-house built open-irrigated MW catheter.

View Article and Find Full Text PDF

Imaging of elbow entrapment neuropathies.

Insights Imaging

January 2025

IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.

Entrapment neuropathies at the elbow are common in clinical practice and require an accurate diagnosis for effective management. Understanding the imaging characteristics of these conditions is essential for confirming diagnoses and identifying underlying causes. Ultrasound serves as the primary imaging modality for evaluating nerve structure and movement, while MRI is superior for detecting muscle denervation.