A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Collagen-hydroxyapatite composite prepared by biomimetic process. | LitMetric

Collagen-hydroxyapatite composite prepared by biomimetic process.

J Biomed Mater Res A

Bone Biomaterial Unit, School of Pathology, Faculty of Medical Sciences, University of New South Wales, Sydney 2052, Australia.

Published: January 2004

A novel bone graft substitute comprising a porous, collagenous scaffold was biomimetically coated with hydroxyapatite using a simulated body fluid solution chemistry method. The scaffold had a porosity of approximately 85%, with pore sizes between 30 microm and 100 microm. Glutaraldehyde vapor was used to stabilize the collagenous scaffold, giving a significantly increased thermal stability over an unstabilized scaffold, as shown by differential scanning calorimetry. A thin layer (<10 microm) of crystalline hydroxyapatite was deposited onto the stabilized collagenous scaffold by soaking the collagenous construct in simulated body fluid in the presence of calcium silicate glass. The presence of crystalline hydroxyapatite was confirmed by X-ray diffraction, energy-dispersive X-ray spectroscopy, and scanning electron microscopy. In vitro cytotoxicity testing of the composite construct using L-929 fibroblasts (ISO 10993-5) and rabbit periosteal cells revealed a cytocompatible material that supported cellular attachment and proliferation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.20031DOI Listing

Publication Analysis

Top Keywords

collagenous scaffold
8
collagen-hydroxyapatite composite
4
composite prepared
4
prepared biomimetic
4
biomimetic process
4
process novel
4
novel bone
4
bone graft
4
graft substitute
4
substitute comprising
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!