Primary factors affecting maximum torsional loading of the tibia in running.

Sports Biomech

Laboratory of Sports Sciences, Department of Life Sciences, University of Tokyo, Meguro, Tokyo, Japan.

Published: July 2002

The purpose of this study was to determine primary factors that contribute to the magnitude of the maximum torsional moment on the tibia during running based on information from three-dimensional shank kinematics and ground reaction forces. Eight male subjects were asked to run along a straight track at 5.0 m s-1. Data were collected using two high-speed cameras and a force platform. Each subject's left foot and tibia were modelled as a system of coupled rigid bodies. First, net axial moments acting at both ends of the tibia were calculated using inverse dynamics. Then the tibial torsional moment was determined from the quasi-equilibrium balance of the net tibial axial moments. Our results showed considerable inter-individual variations for the tibial torsional moment during the stance phase of running. The maximum torsional moment reflecting external rotational loading of the proximal tibia was significantly correlated with the outward tilt angle of the shank in the frontal plane (r = 0.78, p < 0.05) and with the vertical force of ground reaction (r = 0.70, p < 0.05). In conclusion, lowering tibial torsional loading by interventions based on the present findings may lead to the reduction of running injuries that occur in athletes' tibiae.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14763140208522795DOI Listing

Publication Analysis

Top Keywords

torsional moment
16
maximum torsional
12
tibial torsional
12
primary factors
8
torsional loading
8
tibia running
8
ground reaction
8
axial moments
8
torsional
6
tibia
5

Similar Publications

Objective: To explore changes of humerus torque screw tip distance on stability of proximal humeral internal locking system (PHILOS) by finite element analysis, in order to provide reference for selection of intraoperative plant size.

Methods: The proximal humerus 3D model was constructed based on Synbone artificial bone model in 3D engineering drawing software, and the corresponding 3D model was constructed based on PHILOS bone plate contour. The model was modified to simulate comminuted proximal humerus fracture, and the operation model was simulated after fracture, and the fixed operation model was assembled, the apex distance of humerus moment screw was set as 4, 8, 12 and 16 mm respectively.

View Article and Find Full Text PDF

Aromatic organometallic complexes, such as ferrocene and the "inverse sandwich complex" [NaCp], are stabilized via charge-transfer (C-T) interactions and cation-π interactions (i.e., charge-induced dipole and charge-quadrupole interactions).

View Article and Find Full Text PDF

Additive CHARMM Force Field for Pterins and Folates.

J Comput Chem

January 2025

Laboratoire d'Optique et Biosciences (CNRS UMR7645, INSERM U1182), Ecole Polytechnique, Institut polytechnique de Paris, Palaiseau, France.

Folates comprise a crucial class of biologically active compounds related to folic acid, playing a vital role in numerous enzymatic reactions. One-carbon metabolism, facilitated by the folate cofactor, supports numerous physiological processes, including biosynthesis, amino acid homeostasis, epigenetic maintenance, and redox defense. Folates share a common pterin heterocyclic ring structure capable of undergoing redox reactions and existing in various protonation states.

View Article and Find Full Text PDF

Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure.

Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides.

View Article and Find Full Text PDF

Background: The optimal treatment for Pauwels type III femoral neck fractures remains contentious. We aim to compare the biomechanical properties of three inverted cannulated compression screw (ICCS), femoral neck system (FNS), and percutaneous compression plate (PCCP) to determine which offers superior stability for unstable femoral neck fractures.

Materials And Methods: Finite element analysis and artificial bone models were used to establish Pauwels III femoral neck fracture models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!