The radiographs of 46 consecutive polyethylene cups used in cemented first-time revision of the acetabulum were studied up to a mean of 10.7 years (range, 0.5-16.3 years). Six cups developed loosening, of which 2 were revised. New radiolucent lines appeared mainly up to the 3 years follow-up. Progression of radiolucencies to new regions was noted in 28 (61%) cups. This progression occurred as an increase in extension from the periphery to the central region of the interface, whereas the width only showed minor changes. Our findings indicate that even radiolucent lines with a width <1.0 mm should be given attention because these lines can surround the cup before significant migration (>5 mm) is established. True lateral radiographs exposed to visualize the interface add information concerning presence of loosening. According to our opinion, complete radiolucent lines on either the anterior-posterior or lateral view, with a width of 0.3 to 0.5 mm or more, should be regarded as radiographic failure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0883-5403(03)00405-4DOI Listing

Publication Analysis

Top Keywords

radiolucent lines
12
first-time revision
8
radiographic evaluation
4
evaluation charnley
4
cups
4
charnley cups
4
cups first-time
4
revision repeated
4
repeated observations
4
observations 7-15
4

Similar Publications

Mid-term outcomes after primary total hip arthroplasty with a cemented short stem in an elderly patient cohort.

Arch Orthop Trauma Surg

December 2024

Department of Orthopedics and Trauma Surgery, Ospedale Civile Maggiore Di Borgo Trento, University of Verona, Piazzale Aristide Stefani, 1, 37126, Verona, VR, Italy.

Purpose: The main objective of this prospective study was to assess clinical, radiographic and safety mid-term outcomes after THA with a short cemented stem in an elderly patient cohort. Moreover, the study aimed at investigating the mid-term survivorship of the implant and the incidence of complications.

Methods: 96 consecutive patients (100 cases) underwent THA with a short cemented stem.

View Article and Find Full Text PDF

Background: Indications for primary total knee arthroplasty (TKA) have become more inclusive of morbidly obese patients, however, higher rates of complications and lower implant survival have also been reported in this population. The purpose of this study was to investigate the mid-term survival, clinical, and radiographic outcomes of a cementless trabecular metal monoblock tibial component in severely obese patients.

Methods: This was a retrospective study of class II and III obese (BMI > 35) patients who received a cementless primary TKA.

View Article and Find Full Text PDF
Article Synopsis
  • Initial hinge designs for total knee arthroplasty had issues with loosening, but this study focuses on contemporary rotating-hinge implants.
  • A retrospective review of 54 surgeries from 2014 to 2018 showed promising outcomes, with a patient demographic mostly of older women dealing with severe knee instability.
  • Results indicated a 95% reoperation-free survival rate at 2 and 5 years, significant improvements in patient-reported quality of life, and no signs of aseptic loosening on follow-up imaging.
View Article and Find Full Text PDF

Purpose: Reverse shoulder arthroplasty (RSA) is a common surgical procedure for elderly patients with proximal humerus fractures. Cement fixation of the humeral stem is considered the gold standard for this procedure. Due to the high prevalence of osteoporosis in this patient population, the risk of intraoperative fractures is increased when uncemented stems are used.

View Article and Find Full Text PDF
Article Synopsis
  • A study was conducted on ceramic-on-metal hip replacements originally performed from 2007 to 2009 to assess their long-term outcomes after 5.8 and 10.1 years.
  • The revision rates increased from 3.1% at six years to 8.8% at ten years, with a notable rise in pain scores and decline in overall hip function during that time.
  • The findings revealed significant issues like increased radiolucent lines in X-rays and higher metal ion levels, indicating that the survival rate for these implants dropped to 91.2%, below the recommended threshold, raising concerns for future implant designs.
View Article and Find Full Text PDF