A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monitoring well interception with fractures in clayey till. | LitMetric

Monitoring well interception with fractures in clayey till.

Ground Water

Technical University of Denmark, Institute of Environment and Resources, DK-2800, Lyngby, Denmark.

Published: March 2004

When using monitoring wells for investigation of contaminant sources in clayey till, there is a high risk that fractures may cause mobile contaminants to bypass the monitoring wells. This paper indicates that the probability of interception between monitoring wells and hydraulic conductive fractures is often significantly less than 50%. Based on a field experiment and application of a calibrated discrete fracture matrix diffusion numerical model (FRAC3Dvs), the paper also evaluates pesticide-monitoring results for different positions of monitoring well screen relative to fractures. For well screens situated 0.25 and 2 m from a conductive fracture, the first concentrations of the pesticide metabolite (2,6 dichlorobenzamide, "BAM") would be measured two years and 18 years, respectively, after the contaminant had been transported into an underlying aquifer. In this way, underlying aquifers may be subjected to contamination by downward moving contamination without being observed in monitoring wells in the till.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1745-6584.2003.tb02418.xDOI Listing

Publication Analysis

Top Keywords

monitoring wells
16
monitoring well
8
clayey till
8
monitoring
6
well interception
4
fractures
4
interception fractures
4
fractures clayey
4
till monitoring
4
wells
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!