Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Optical coherence tomography (OCT) is a new ophthalmic imaging modality generating cross sectional views of the retina. OCT systems are essentially Michelson interferometers that form images in 1.5 s by directing a superluminescent diode (SLD) beam over the retinal surface. Involuntary eye motions frequently cause incorrect locations to be imaged. This motion may leave no obvious artifacts in the scan data and can easily go undetected. For glaucoma monitoring especially, knowing the measurement path, typically a circle concentric with the nerve head, is crucial. The commercially available OCT system displays a near-infrared video of the retina showing the SLD beam. This paper presents a prototype system to detect the nerve head and SLD beam in the video, and report the true scan path relative to the nerve head. Low image contrast and limited resolution make the reliable detection of retinal features difficult. In an adaptive model construction phase, the system directly detects retinal vasculature and the nerve head and incrementally builds a model of the current subject's vascular pattern relative to the optic disk. The nerve head identification is multitiered, using a novel dual eigenspace technique and a geometric comparison of detected vessel positions and nerve head hypotheses. In its operational phase, a correspondence is achieved between the currently detected vasculature and the model. Using subjects not included in training, the system located the optic nerve head to within 5 pixels (0.07 optic disk diameters, an error well below clinical significance) in 99.75% of 2800 video fields. In current clinical practice, motions as large as 1-2 disc diameters may go undetected, so this is a vast improvement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TMI.2003.817753 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!