Studies have concluded that the shape of the human mitral valve annulus is a three-dimensional saddle. The objective of this study was to investigate the effects of a saddle shaped annulus on chordal force distribution and mitral valve function. Eleven human mitral valves were studied in a physiological left heart simulator with a variable shaped annulus (flat versus saddle). Cardiac output and transmitral pressure were analyzed to determine mitral regurgitation volume. In six experiments, force transducers were placed on six chordae tendineae to measure chordal force distribution. Valves were tested in normal and pathophysiologic papillary muscle positions. When comparing the flat and saddle shaped configurations, there was no significant difference in mitral regurgitation volume 11.2% +/- 24.7% (p = 0.17). In the saddle shaped configuration, the tension on the anterior strut chord was reduced 18.5% +/- 16.1% (p < 0.02), the tension on the posterior intermediate chord increased 22.3% +/- 17.1% (p < 0.03), and the tension of the commissural chord increased 59.0% +/- 32.2% (p < 0.01). Annular shape also altered the tensions on the remaining chords. Annular shape alone does not significantly affect mitral regurgitation caused by papillary muscle displacement. A saddle shaped annulus redistributes the forces on the chords by altering coaptation geometry, leading to an optimally balanced anatomic/physiologic configuration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1114/1.1616929 | DOI Listing |
Accid Anal Prev
December 2024
Nanjing Hurys Intelligence Technology Co., LTD, Nanjing 210000, China.
To deepen the understanding of the impact of car-following driving style (CFDS) on traffic conflict risk and address the lack of clear CFDS evaluation metrics, this study proposes an improved CFDS metric based on the Asymmetric Behavior (AB) theory. Interpretable machine learning models were utilized for regression analysis to examine the relationship between CFDS and conflict risk. The generalized AB model calculates the difference between vehicle trajectories and the Newell trajectory, constructing the driving style evaluation metric, which quantifies driver aggressiveness in a manner that is both computationally straightforward and easily interpretable.
View Article and Find Full Text PDFPurpose: Assessing scapulothoracic kinematics typically involves visually observing patients during movement, which has limited inter- and intraobserver reliability. Dynamic rasterstereography (DRS) records, measures and visualizes surface structures in real time, using a curvature map to colour-code convex, concave and saddle-shaped structures on the body surface. This study aimed to evaluate the diagnostic efficacy of DRS-assisted observation in identifying dyskinetic scapulothoracic patterns.
View Article and Find Full Text PDFJ Phys Chem Lett
December 2024
Institute of Molecular Plus, Tianjin University, Tianjin 300072, P. R. China.
Intramolecular singlet fission (SF) in multichromophore systems is of high interest for photovoltaic application. As an attractive candidate for SF-based devices, enabling efficient SF in covalent oligomers of perylene diimide (PDI) still remains challenging. In this work, inter-PDI SF with τ = ∼150 ps and ∼150% triplet yield in a covalent tetramer COTh-FPDI was facilitated by employing a saddle-shaped cyclooctatetrathiophene (COTh) core and fused linking with PDIs.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
Organisch-Chemisches Institut, Universität Heidelberg, Im Neuenheimer Feld 270, 69120, Heidelberg, Germany.
The very first representative of trithia-bridged N-heterotriangulene, a triphenylamine with sulfur atoms bridging the ortho-positions, was synthesized by a sequence of regioselective sulfenylation with phthalimidesulfenyl chloride followed by Lewis acid-catalyzed electrophilic cyclization. X-ray crystallography revealed a saddle-shaped geometry of the polycyclic scaffold. UV/Vis absorption spectroscopy and cyclic voltammetry were used to characterize the optoelectronic properties.
View Article and Find Full Text PDFInterdiscip Cardiovasc Thorac Surg
December 2024
Klinik für Herz-, Thorax- und Gefäßchirurgie Deutsches Herzzentrum der Charité, Berlin, Germany.
Objectives: Memo 4D is a semi-rigid ring with an exclusive saddle shape and progressive increased anteroposterior diameter. This preliminary analysis reports 30-day clinical and haemodynamic outcomes of the MANTRA Memo 4D sub-study.
Methods: MANTRA is an "umbrella" prospective, multicentre, worldwide post-market study to collect real-life safety and performance data on the Corcym devices.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!