The aim of this study was to compare the image quality of a saturation-recovery gradient-recalled echo (GRE; TurboFLASH) and a saturation-recovery SSFP (SR-TrueFISP) sequence for myocardial first-pass perfusion MRI. Eight patients with chronic myocardial infarction and 8 volunteers were examined with a TurboFLASH (TR 2.1 ms, TE 1 ms, FA 8 degrees ) and a SR-TrueFISP sequence (TR 2.1 ms, TE 0.9 ms, FA, 50 degrees ) on a 1.5 T scanner. During injection of 0.05 mmol/kg BW Gd-DTPA at 4 ml/s, three short axis slices (8 mm) of the left ventricle (LV) were simultaneously scanned during breath-hold. Maximum signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) between infarcted and normal myocardium, and percentage signal intensity change (PSIC) were measured within the LV lumen and in four regions of the LV myocardium for the three slices separately. For the LV lumen, SR-TrueFISP was superior in SNR and PSIC (factor 3.2 and 1.6, respectively). Mean maximum SNR, PSIC, and CNR during peak enhancement in the LV myocardium were higher for SR-TrueFISP compared with TurboFLASH (factor 2.4, 1.25, and 1.24, respectively). The SNR was higher in the septal portion of the ventricle than in anterior/posterior and lateral regions. The SR-TrueFISP provides higher SNR and improves image quality compared with TurboFLASH in first-pass myocardial perfusion MRI.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-003-2176-1DOI Listing

Publication Analysis

Top Keywords

myocardial first-pass
8
first-pass perfusion
8
image quality
8
sr-truefisp sequence
8
perfusion mri
8
snr psic
8
compared turboflash
8
turboflash
5
sr-truefisp
5
snr
5

Similar Publications

Artifacts at Cardiac MRI: Imaging Appearances and Solutions.

Radiographics

January 2025

From the Department of Radiology, Cardiovascular Imaging, Mayo Clinic, 200 1st St SW, Rochester, MN 559905 (P.S.R., P.A.A.); Department of Radiology, Division of Cardiothoracic Imaging, Jefferson University Hospitals, Philadelphia, Pa (B.S.); Department of Radiology, Baylor Health System, Dallas, Tex (P.R.); Department of Diagnostic Radiology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR (M.Y.N.); and Department of Diagnostic Radiology, Cleveland Clinic, Cleveland, Ohio (M.A.B.).

Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR.

View Article and Find Full Text PDF

Coronary computed tomography angiography (CCTA) is a powerful tool to rule out coronary artery disease (CAD). In the last decade, myocardial perfusion CT (CTP) technique has been developed for the evaluation of myocardial ischemia, thereby increasing positive predictive value for diagnosis of obstructive CAD. A diagnostic strategy combining CCTA and perfusion acquisitions provides both anatomical coronary evaluation and functional evaluation of the stenosis, increasing the specificity and the positive predictive value of cardiac CT.

View Article and Find Full Text PDF

Background: Very high power and short duration (vHPSD) ablation is recently used for pulmonary vein isolation. However, low first-pass isolation rates have been reported, possibly because of shallow lesion formation, necessitating deeper lesions to improve treatment outcomes.

Objective: This study aimed to confirm the safety and efficacy of double radiofrequency applications of vHPSD ablation in an in vivo beating swine heart model.

View Article and Find Full Text PDF
Article Synopsis
  • - The study evaluates the effectiveness of quantitative perfusion cardiac magnetic resonance (QP-CMR) imaging in detecting significant coronary artery disease (CAD) in patients with a history of CAD and new chest pain, comparing it with visual assessment of stress perfusion CMR and quantitative PET imaging.
  • - Involving 145 patients with prior heart issues, the research found QP-CMR's sensitivity at 66%, which is lower than PET at 80%, but its specificity is on par with both v-CMR and PET at about 60-63%.
  • - Overall, the study concludes that QP-CMR's diagnostic performance is similar to that of both other imaging methods for identifying hemodynamically significant CAD, defined by fractional
View Article and Find Full Text PDF

Quantitation of mitral regurgitation using positron emission tomography.

EJNMMI Res

September 2024

Molecular Imaging and Medical Physics, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.

Background: Cardiac positron emission tomography (PET) offers non-invasive assessment of perfusion and left ventricular (LV) function from a single dynamic scan. However, no prior assessment of mitral regurgitation severity by PET has been presented. Application of indicator dilution techniques and gated image analyses to PET data enables calculation of forward stroke volume and total LV stroke volume.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!