A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A prospective, blinded study of diagnostic esophagoscopy with a superthin, stand-alone, battery-powered esophagoscope. | LitMetric

Objectives: A more widely available, well-tolerated, and cost-effective technique is needed to screen a broad population at risk for esophageal cancer. An ideal solution might be to perform unsedated esophagoscopy with an entirely self-contained, small-caliber endoscope. In a prospective, blinded study in three phases, we compared the feasibility, patient tolerance, and diagnostic accuracy of esophagoscopy performed with a prototype, superthin, battery-powered esophagoscope (BPE) with standard video esophagogastroduodenoscopy (SVE).

Methods: In phase I, 10 healthy volunteers underwent both peroral and transnasal esophagoscopy with BPE to evaluate the technical feasibility of the examination. For phases II and III, patients were recruited to have BPE before SVE. In phase II, both procedures were performed with conscious sedation. In phase III, the BPE was performed with only topical anesthesia. Two endoscopists assessed the technical performance of the endoscope and patient tolerance and recorded the esophageal findings independently.

Results: In phase I, all endoscopists reported adequate visualization of the esophagus in the 10 volunteers. A total of 181 patients were evaluated in phases II and III (89 in phase II, 92 in phase III). The sensitivity for detecting columnar lined esophagus was 94% in phase II and 95% in phase III. The sensitivity for all esophageal findings was 87% and 86% in phases II and III, respectively. The technical performance of the endoscope was significantly worse for BPE compared with the SVE. The patient tolerance as evaluated by the endoscopist was similar for both procedures. Ninety-five percent of the patients undergoing unsedated BPE were willing to have the procedure repeated under similar circumstances.

Conclusions: Unsedated esophagoscopy with a 3.1-mm, battery-powered, stand-alone esophagoscope is feasible, well tolerated, and accurate in detecting esophageal pathologies. It might be an efficient and cost-effective screening tool for the detection of columnar lined esophagus.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1572-0241.2003.08701.xDOI Listing

Publication Analysis

Top Keywords

patient tolerance
12
phases iii
12
phase iii
12
prospective blinded
8
blinded study
8
battery-powered esophagoscope
8
unsedated esophagoscopy
8
phase
8
technical performance
8
performance endoscope
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!