Tissue-Doppler echocardiography (TDE) has been introduced to quantify stress echocardiography by means of assessing the left ventricular (LV) segmental myocardial velocities and excursion. The interaction between LV long- and short-axis function during physical exercise has not been elucidated completely. The aim of the present study was to investigate long- and short-axis LV function, as assessed by myocardial velocities and excursions at rest and during exercise and its possible relationship with heart rate in healthy elderly individuals by TDE. Twenty-seven individuals underwent an exercise test in the supine position on a bicycle ergometer. The initial workload was 30 Watts, followed by 20-Watt increments every third minute. Standard echocardiographic images with super-imposed colour TDE were digitized at the end of each step. The following variables were studied in the LV long- and short-axis: myocardial peak systolic velocity (PSV) and excursion, isovolumic contraction and relaxation times, peak velocity at early diastole (E'-wave) and peak velocity at late diastole (A'-wave) and the E'/A' ratio. Increments in myocardial peak systolic velocity and excursion in the LV long-axis were more pronounced during low workloads. The increase in those variables in the short-axis occurred mainly at higher exercise loads. The improvement in LV long- and short-axis functions was closely related to the increase in the heart rate. Shortening of the isovolumic contraction and relaxation times occurred only at the initial stages of exercise. An increase in the long-axis E'/A' ratio occurred during exercise, whereas this ratio was unchanged in the short-axis. In conclusion, during exercise, the LV long- and short-axis functions behave differently, and increases in LV long- and short-axis functions are related to changes in heart rate. Therefore, in the interpretation of echocardiographic findings during exercise stress echocardiography, these facts have to be taken into account.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1042/CS20030259 | DOI Listing |
Med Phys
December 2024
Department of Echocardiography, Ultrasound Diagnostic Center, The First Hospital of Jilin University, Changchun, China.
Background: Dialysis Access (DA) stenosis impacts hemodialysis efficiency and patient health, necessitating exams for early lesion detection. Ultrasound is widely used due to its non-invasive, cost-effective nature. Assessing all patients in large hemodialysis facilities strains resources and relies on operator expertise.
View Article and Find Full Text PDFDiseases
November 2024
Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Giessen and Marburg, Philipp University of Marburg, Baldingerstraße, 35037 Marburg, Germany.
Purpose: To evaluate the ability of acoustic radiation force impulse (ARFI) elastography in differentiating benign from malignant etiologies of splenomegaly based on differences in splenic stiffness.
Materials And Methods: Between September 2020 and November 2022, we evaluated 40 patients with splenomegaly-defined by a splenic long axis greater than 13 cm and/or a short axis greater than 6 cm, without visible focal or infiltrative mass lesions-using abdominal ultrasound at our university hospital. Each patient also underwent a standardized ARFI elastographic assessment of the enlarged spleen, with data collected prospectively.
Infect Drug Resist
December 2024
Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People's Republic of China.
Purpose: Periprosthetic joint infection (PJI) is a severe complication following joint replacement surgery, and there is a current lack of rapid, accurate, and non-invasive diagnostic methods. This study aims to assess the effectiveness of using dual-energy computed tomography (DECT) to quantify the maximum long and short axes of the external iliac lymph nodes (LNs) as a diagnostic tool for PJI.
Patients And Methods: In this prospective controlled study, 112 patients undergoing total hip or total knee revision surgery were enrolled.
Clin Imaging
December 2024
Department of Radiology, Mianyang Central Hospital, School of Medicine, University of Electronic Science and Technology of China, No. 12 Changjia Lane, Alarm Bell St, Fucheng District, Mianyang 621000, China. Electronic address:
Purpose: To investigate differences in left ventricular wall thickness (LVWT) measurements between end-diastole and mid-diastole using cardiac computed tomography (CCT) and establish LVWT reference values stratified by phase, sex, and region.
Methods: Subjects who underwent CCT without a history of cardiovascular disease or risk factors were retrospectively included between 2021 and 2024. LVWT was manually measured in each segment according to the American Heart Association's 17-segment model at end-diastole and mid-diastole.
Quant Imaging Med Surg
December 2024
Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Background: Segmented cine imaging using a balanced steady-state free precession sequence is the gold standard for accurately quantifying cardiac function and myocardial mass. However, this method suffers from inefficient K-space sampling, resulting in long scan times, and requires multiple breath holds that can be difficult for some patients. Real-time compressed sensing (CS) cine reduces image acquisition time through K-space undersampling and iterative reconstruction, enabling rapid magnetic resonance (MR) imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!