A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Distal filter protection during percutaneous coronary intervention in native coronary arteries and saphenous vein grafts in patients with acute coronary syndromes. | LitMetric

Background: Percutaneous coronary interventions on saphenous vein grafts (SVG) and in patients with acute coronary syndromes (ACS) have been associated with the distal embolization of the thrombus and plaque and to the no-reflow phenomenon. We report on the safety and feasibility of a new distal emboli protection filter.

Methods: Angioplasty using distal filter protection (Angioguard, Cordis, Warren, NJ, USA) was attempted in 38 patients (mean age 65 +/- 11 years, 79% males) affected by ACS. A percutaneous coronary intervention was performed in 27 native coronary arteries, in 10 SVG and in one arterial graft (mean diameter stenosis 88 +/- 9%). Patients with vessels presenting severe proximal tortuosity, more than mild calcification, a diameter < 3.0 mm and a lesion length > 15 mm were excluded.

Results: It was possible to position the device in all patients (100%); in 7 patients (18%) the lesion could be crossed with the filter only after balloon predilation. Procedural success with final TIMI flow 3 was obtained in all patients and the mean residual diameter stenosis after stent implantation was 5 +/- 8%. Transient procedural complications without clinical sequelae included the no-reflow phenomenon (2 patients, 5%) and vessel perforation (1 patient, 2.5%). In no case was distal embolization observed. As regards the device-related complications, one occlusive dissection (2.5%) occurred and was successfully treated with stent implantation. In-hospital and 30-day major adverse cardiac events consisted of two non-Q wave myocardial infarctions (5%), both occurring during SVG interventions.

Conclusions: The use of the Angioguard filter for preselected lesions in patients with ACS had a high technical success and carried a low rate of device-related complications. The clinical efficacy of the device needs further evaluation.

Download full-text PDF

Source

Publication Analysis

Top Keywords

percutaneous coronary
12
patients
9
distal filter
8
filter protection
8
coronary intervention
8
native coronary
8
coronary arteries
8
saphenous vein
8
vein grafts
8
patients acute
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!