Purpose: To establish fast, high-resolution in vivo cine magnetic resonance imaging (cine-MRI) on a vertical 11.7-T MR system and to investigate the stability of normal and failing mouse hearts in the vertical position.

Materials And Methods: To optimize the method on a high-field system, various MR-related parameters, such as relaxation times and the need for respiratory gating, were quantitatively investigated. High-resolution cine-MRI was applied to normal mice and to a murine heart failure model. Cardiac functional parameters were compared to matched mice imaged previously on a horizontal MR system.

Results: A T(1) of 1.10 +/- 0.27 seconds and a T(2) of 18.5 +/- 3.9 msec were measured for murine myocardial tissue. A quantitative analysis also proved respiratory gating to be essential for obtaining artifact-free cine images in the vertical position at this field strength. Cardiac functional parameters of mice, obtained within one hour, agreed well with those from previous studies of mice in the horizontal position.

Conclusion: This work shows that MR systems with a vertical bore design can be used to accurately measure cardiac function in both normal and chronically failing mouse hearts within one hour. The increased signal-to-noise ratio (SNR) due to the higher field strength could be exploited to obtain higher temporal and spatial resolution compared to previous studies that were performed on horizontal systems with lower field strengths.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.10411DOI Listing

Publication Analysis

Top Keywords

failing mouse
12
mouse hearts
12
fast high-resolution
8
high-resolution vivo
8
vivo cine
8
cine magnetic
8
magnetic resonance
8
resonance imaging
8
normal failing
8
hearts vertical
8

Similar Publications

Aims/hypothesis: Diabetic kidney disease (DKD) features intrarenal inflammation, in which T cells play a part. Hypoxia-inducible factor-1α (HIF-1α), a key transcription factor regulating cellular responses to hypoxia, is reportedly involved in the course of inflammation. The role of HIF-1α in DKD has been investigated, but the conclusions are controversial so far.

View Article and Find Full Text PDF

The primary cilium is a microtubule-based organelle that cycles through assembly and disassembly. In many cell types, formation of the cilium is initiated by recruitment of ciliary vesicles to the distal appendage of the mother centriole. However, the distal appendage mechanism that directly captures ciliary vesicles is yet to be identified.

View Article and Find Full Text PDF

Na1.7 is considered a promising target for developing next-generation analgesic drugs, given its critical role in human pain pathologies. Although most reported inhibitors with strong in vitro activity and high selectivity share the aryl sulfonamide scaffold, they failed to demonstrate marked clinical efficacy.

View Article and Find Full Text PDF

Metabolic dysfunction-associated steatotic liver disease (MASLD) is a highly prevalent liver pathology in need of novel pharmacological treatments to complement lifestyle-based interventions. Nuclear receptor agonists have been under scrutiny as potential pharmacological targets and as of today, resmetirom, a thyroid hormone receptor b agonist, is the only approved agent. The dual PPAR α and δ agonist elafibranor has also undergone extensive clinical testing, which reached the phase III clinical trial but failed to demonstrate a beneficial effect on MASLD.

View Article and Find Full Text PDF

Purpose: Study the scotopic oscillatory potentials (OPs) in mice over a wide range of flash luminance levels using the Hilbert transform (HT) to extract new features of the high frequency components of the electroretinogram (ERG).

Methods: Scotopic ERGs [Intensity: - 6.3 to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!