Spectral sensitivity in eyes with macular holes and their fellow eyes.

Clin Exp Optom

Optometry Department, Faculty of Allied Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda 50300, Kuala Lumpur, Malaysia.

Published: November 2003

Background: This prospective study was undertaken to investigate whether spectral sensitivity can be useful in determining the prognosis of fellow eyes of eyes with macular holes.

Methods: Spectral sensitivity measurements using a one degree test spot presented at a rate of 1 Hz and 25 Hz on a bright (1000 td) white background were carried out on 10 patients aged between 67 and 74 years (mean age 70.3 +/- 2.6 years). Each patient had a full thickness macular hole in one eye and a normal contralateral fellow eye. The spectral sensitivity measurements were made with eccentric fixation in the eyes with macular holes and with central fixation in the normal fellow eye. A year later, the patient files were reviewed to look at the patient's ocular condition. Another 10 subjects between the ages of 50 and 80 years (mean age 69.5 +/- 4.2 years) were also seen. These control group subjects had visual acuities of 6/9 or better with minimal ocular media changes and no ocular or systemic pathology that could affect colour vision.

Results: The 1 Hz and 25 Hz spectral sensitivities of all patients were reduced for both eyes. Despite the good eye without a macular hole having a VA of 6/6, the spectral sensitivity was similar to that of the eye with the macular hole and markedly reduced visual acuity.

Conclusion: The present investigation enabled us to examine the chromatic and achromatic mechanisms by testing spectral sensitivity at 1 Hz and 25 Hz, respectively. The data revealed that both chromatic and achromatic processing could be damaged in the eye with a macular hole. Surprisingly, the spectral sensitivities of both 1 Hz and 25 Hz are equally reduced in the good fellow eye with no macular hole. A one-year follow-up showed that two of the 10 patients (20 per cent) did eventually develop a macular hole in the normal fellow eye. This indicates that there is some subclinical foveal dysfunction in the normal fellow eye, the nature of which is unclear.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1444-0938.2003.tb03083.xDOI Listing

Publication Analysis

Top Keywords

spectral sensitivity
24
macular hole
24
fellow eye
20
eye macular
16
eyes macular
12
normal fellow
12
macular
9
eye
9
spectral
8
macular holes
8

Similar Publications

This study investigates the optical properties of carbon nanotubes (CNTs) and silicene nanotubes (SiNTs) under the influence of external magnetic fields, focusing on their linear and nonlinear optical responses. A tight-binding model is employed to analyze the effects of magnetic fields on the electronic band structure, dipole matrix elements, and various optical susceptibilities of zigzag CNTs and SiNTs. The results reveal significant magnetic field-induced modifications in both linear and nonlinear optical spectra.

View Article and Find Full Text PDF

Molecular vibrations of acetylacetone enol. Infrared polarization spectroscopy and theoretical predictions.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Department of Science and Environment, Roskilde University, Universitetsvej 1, P.O. Box 260, DK-4000 Roskilde, Denmark. Electronic address:

The IR polarization spectrum of acetylacetone enol (AAe, (3Z)-4-hydroxy-3-penten-2-one) was recorded in the region 2000 - 450 cm using stretched polyethylene as an anisotropic solvent. The measured orientation factors were consistent with C molecular symmetry of AAe and provided an experimental distinction between in-plane and out-of-plane polarized spectral features. The results suggest the assignment of at least one previously unrecognized fundamental transition.

View Article and Find Full Text PDF

Background: Identifying spontaneous circulation during cardiopulmonary resuscitation (CPR) is challenging. Current methods, which involve intermittent and time-consuming pulse checks, necessitate pauses in chest compressions. This issue is problematic in both in-hospital cardiac arrest and out-of-hospital cardiac arrest situations, where resources for identifying circulation during CPR may be limited.

View Article and Find Full Text PDF

Quantitative electroencephalography predicts postoperative delirium in adult cardiac surgical patients from a prospective observational study.

Sci Rep

December 2024

State Key Laboratory of Bioelectronics, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 210009, China.

The diagnostic and prognostic value of quantitative electroencephalogram (qEEG) in the the onset of postoperative delirium (POD) remains an area of inquiry. We aim to determine whether qEEG could assist in the diagnosis of early POD in cardiac surgery patients. We prospectively studied a cohort of cardiac surgery patients undergoing qEEG for evaluation of altered mental status.

View Article and Find Full Text PDF

We present novel fluorescent cholesteryl probes (CNDs) with a modular design based on the solvatochromic 1,8-phthalimide scaffold. We have explored how different modules-linkers and head groups-affect the ability of these probes to integrate into lipid membranes and how they distribute intracellularly in mouse astrocytes and fibroblasts targeting lysosomes and lipid droplets. Each compound was assessed for its solvatochromic behavior in organic solvents and model membranes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!